Tune
Energy Switch | Out (High En) |
Solenoid 1 | 12.4 A |
Solenoid 2 | 7.3 A |
Gun Hor | -0 A |
Gun Ver | +0.2 A |
Output Hor | -0.3 A |
Output Ver | -0 A |
Rep Rate | 17 |
Gun HV | 10 (Knob Setting) |
Gun Grid Voltage | 10 (Knob Setting) |
RF frequency | 2856.315 MHz |
Modulator HV Power Supply | 4.19 (Knob Setting) |
RF macro Pulse Length (FWHM) | 300 ns |
Q1 (A) | -3 |
Q2 (A) | +0 |
Q3 (A) | +2 |
Q4 (A) | 0 |
Q5 (A) | 0 |
Q6 (A) | 0 |
Current at FC0 | 100 mA |
Beam Current Calibration of Scint Left
Determine if the Beam Left Scintillator is linear with beam current.
Determine if the Beam Left Scintillator is linear with beam current.
Beam Current Calibration of Scint Left
Determine if the Beam Left Scintillator is linear with beam current.
1. T1 out, disable D1 (Q4,Q5,Q6 too), send the beam to FC0, take scope image of the area.
2. T1 in, enable D1 (Q4,Q5,Q6 too), bend the beam by 90 deg, take a run with 1000 events.
1.22 nV s /ADC channel
Energy calibration of Scint 1
With T1 ande T2 out, send 1,2,6, and 10 MeV electrons to Scintillator 1 located at the end of the 90 degree beam line
HV=1300
run# | Electron Energy (MeV) | Attenuation (dB) | ADC2 |
3714 | 10 | 27.5 | 3009 |
3715 | 6 | 27.5 | 2935 |
3716 | 4 | 27.5 | 3018 |
Inserted gun triggers into Scaler channel 2
Resume positron production using 10 MeV eletrons
Insert Gun trigger into VME scaler
Set D2 for 2 MeV
D1 is set to 4.2 Amps, and D2 is set to 4.41 Amps.
run# | T1 | T2 | Sweep Magnet | logic | HV-D2L | HV-D1R | Reprate | start | stop | Int Rate | comments |
3719 | in | in | out | (DL & GunTrig) & (DR & GunTrig) | 1150V | 1150V | 200 | 11:03:02 | 11:21:58 | 4.2 events/s | 206540 beam pulses |
3720 | in | in | out | (DL & GunTrig) & (DR & GunTrig) | 1150V | 1150V | 200 | 11:29:52 | 11:44:55 | 5.069 events/s | 181148 beam pulses |
3721 | in | out | out | (DL & GunTrig) & (DR & GunTrig) | 1150V | 1150V | 200 | 12:02:31 | 12:17:32 | 3.9 events/s | 180559 beam pulses |
3722 | in | in | out | (DL & GunTrig) & (DR & GunTrig) | 1150V | 1150V | 200 | 12:28:13 | 12:49:47 | 5.3933 events/s | 268067 beam pulses |
3724 | in | in | out | (DL & GunTrig) & (DR & GunTrig) | 1150V | 1150V | 200 | 13:00:34 | 13:21:44 | 4.6719 events/s | Threshold on the DL is set to 52. it was 29. |
3725 | in | out | out | (DL & GunTrig) & (DR & GunTrig) | 1150V | 1150V | 200 | 13:23:03 | 13:38:04 | 3.1237 events/s | |
3726 | in | in | in | (DL & GunTrig) & (DR & GunTrig) | 1150V | 1150V | 200 | 13:41:55 | 13:57:00 | 3.7244 events/s | sweeping magnet in |
during run 3725 the following were lugged into the TDC
TDC0 = Gun trigger TDC1 = ~95 ns delayed Gun trigger TDC5=N aI Left TDC7 = NaI Right TDC9 = NaI Left (CFD) TDC10 = NaI Right (CFD)
Preliminary results with no cuts
Set D2 for 1 MeV
D1 and D2 set to 2.6 Amps
run# | T1 | T2 | Sweep Magnet | logic | HV-D2L | HV-D1R | Reprate | start | stop | Int Rate | comments | events |
3727 | in | in | in | (DL & GunTrig) & (DR & GunTrig) | 1150V | 1150V | 200 | 13:58:53 | 14:14:01 (908 s) | 3.3208 events/s | sweeping magnet in | |
3728 | in | in | out | (DL & GunTrig) & (DR & GunTrig) | 1150V | 1150V | 200 | 14:16:56 | 14:33:35 (999 s) | 4.0302 events/s | sweeping magnet out | |
3729 | in | out | out | (DL & GunTrig) & (DR & GunTrig) | 1150V | 1150V | 200 | 14:34:31 | 14:50:14 (941 s) | 3.2572 events/s | ||
3730 | in | in | out | (DL & GunTrig) & (DR & GunTrig) | 1150V | 1150V | 200 | 14:51:24 | 15:07:44 (980 s) | 4.1088 events/s | ||
3731 | in | out | out | (DL & GunTrig) & (DR & GunTrig) | 1150V | 1150V | 200 | 15:08:28 | 15:26:02 | 3.1478 events/s |
Set D2 for 3 MeV
D1 and D2 set to 2.8 Amps
run# | T1 | T2 | Sweep Magnet | logic | HV-D2L | HV-D1R | Reprate | start | stop | Int Rate | event number |
3735 | in | in | out | (DL & GunTrig) & (DR & GunTrig) | 1150V | 1150V | 300-301 | 15:54:24 | 16:11:06 (1002 s) | 9.0200 events/s | 9045 |
3736 | in | out | out | (DL & GunTrig) & (DR & GunTrig) | 1150V | 1150V | 300-301 | 16:12:15 | 16:27:07 (892 s) | 4.1736 events/s | 3752 |
3737 | in | in | out | (DL & GunTrig) & (DR & GunTrig) | 1150V | 1150V | 300-301 | 16:28:05 | 16:46:19 (1094 s) | 14.2679 events/s | 15361 |
3 MeV runs duration
7-27-12 >stat r3735.dat File: `r3735.dat' Size: 2588672 Blocks: 5072 IO Block: 4096 regular file Device: 902h/2306d Inode: 17448 Links: 1 Access: (0644/-rw-r--r--) Uid: ( 500/ daq) Gid: ( 500/ daq) Access: 2012-07-27 15:54:21.000000000 -0600 Modify: 2012-07-27 16:11:05.000000000 -0600 Change: 2012-07-30 13:00:05.000000000 -0600
16:11:05 - 15:54:21 = 1004 s
7-27-12 >stat r3736.dat File: `r3736.dat' Size: 1081344 Blocks: 2128 IO Block: 4096 regular file Device: 902h/2306d Inode: 17470 Links: 1 Access: (0644/-rw-r--r--) Uid: ( 500/ daq) Gid: ( 500/ daq) Access: 2012-07-27 16:12:12.000000000 -0600 Modify: 2012-07-27 16:27:06.000000000 -0600 Change: 2012-07-30 13:00:05.000000000 -0600
16:27:06 - 16:12:12 = 894 s
7-27-12 >stat r3737.dat File: `r3737.dat' Size: 4489216 Blocks: 8800 IO Block: 4096 regular file Device: 902h/2306d Inode: 17468 Links: 1 Access: (0644/-rw-r--r--) Uid: ( 500/ daq) Gid: ( 500/ daq) Access: 2012-07-27 16:28:02.000000000 -0600 Modify: 2012-07-27 16:46:18.000000000 -0600 Change: 2012-07-30 13:00:05.000000000 -0600
16:46:18 - 16:28:02 = 1096 s
Set D2 for 4 MeV
D1 and D2 at 7.5 Amps.
run# | T1 | T2 | Sweep Magnet | logic | HV-D2L | HV-D1R | Reprate | start | stop | Int Rate | events |
3738 | in | in | out | (DL & GunTrig) & (DR & GunTrig) | 1150V | 1150V | 300-301 | 16:47:31 | 17:00:10 () | 12.2042 events/s | 9237 |
3739 | in | out | out | (DL & GunTrig) & (DR & GunTrig) | 1150V | 1150V | 300-301 | 17:00:51 | 17:15:06 () | 1.9458 events/s | 1661 |
Set D2 for 5 MeV
D1 and D2 at 9.2 Amps.
run# | T1 | T2 | Sweep Magnet | logic | HV-D2L | HV-D1R | Reprate | start | stop | Int Rate | comments |
3740 | in | in | out | (DL & GunTrig) & (DR & GunTrig) | 1150V | 1150V | 300-301 | 17:17:03 | 17:25:31 () | 2.8924 events/s | 1461 |
3741 | in | out | out | (DL & GunTrig) & (DR & GunTrig) | 1150V | 1150V | 300-301 | 17:26:15 | 17:36:27 () | 1.7331 events/s | 1081 |
Rotating Target Simulation
We want to know what happens when the tungsten target on the motor rotates and electron beam misses the target when there is a gap between target(s) .
Dipole magnets and quad magnets are set to 2 MeV positron mode.
run# | T1 | T2 | Sweep Magnet | logic | HV-D2L | HV-D1R | Reprate | start | stop | Int Rate | comments |
3734 | out | in | out | (DL & GunTrig) & (DR & GunTrig) | 1150V | 1150V | 300-301 | 15:37:40 | 15:52:23 | 1.1425 events/s | 1004 |
Look for positrons using 6 MeV electrons
6 MeV electron on T1. Measure scintillator out put as function of slit distance, in electron mode. Set 2 MeV at D1 and D2. At 30 Hz reprate.
3rd Tuning (6 MeV)
Energy Switch | In (Low En Range) |
Solenoid 1 | 6.9 A |
Solenoid 2 | 9.3 A |
Gun Hor | -0.1 A |
Gun Ver | 0 A |
Output Hor | 0.5 A |
Output Ver | 0.3 A |
Rep Rate | 10 |
Gun HV | 10 (Knob Setting) |
Gun Grid Voltage | 10(Knob Setting) |
RF frequency | 2856.780 MHz |
Modulator HV Power Supply | 3.71 (Knob Setting) |
RF macro Pulse Length (FWHM) | 300 ns |
Q1 (A) | 0 |
Q2 (A) | 0 |
Q3 (A) | 0 |
Q4 (A) | 0 |
Q5 (A) | 0 |
Q6 (A) | 0 |
Measured window width is screen (Gating on the scope is set to "Screen" mode).
Check pulse number
source CODA/setup
cd data
xcefdmp
viewfile->Data Source r2838.dat // need to be dat file, not root file.
enter big event number to: Event Num
then go to one event earlier to get last event number.