Camera Trig

Tune the beam for 15 MeV range, see the beam with camera. Get camera triggering.

Tune The Beam for 11-12 MeV

Energy Switch Out (High En)
Solenoid 1 6.8 A
Solenoid 2 1.2 A
Gun Hor -0.1 A
Gun Ver 0 A
Output Hor +0.2 A
Output Ver +0.4 A
Rep Rate 8
Gun HV 10 (Knob Setting)
Gun Grid Voltage 10 (Knob Setting)
RF frequency 2856.272 MHz
Modulator HV Power Supply 4.28 (Knob Setting)
RF macro Pulse Length (FWHM) 300 ns
Q1 (A) -2.6
Q2 (A) -3.2
Q3 (A) -3.6
Q4 (A) -1.5
Q5 (A) +0.7
Q6 (A) -3.6

Beam Current 0 degree FC:

Beam Spot at 0 degree OTR screen:


W1 Time (s) Counts
in 209.1 1842
out 209.1 1842