Difference between revisions of "Beam Test Jul 16 2012"
Jump to navigation
Jump to search
| Line 4: | Line 4: | ||
Tune the beam for 15 MeV range, see the beam with camera. Get camera triggering. | Tune the beam for 15 MeV range, see the beam with camera. Get camera triggering. | ||
| − | = Tune The Beam for | + | = Tune The Beam for 11-12 MeV = |
| − | |||
{| border="1" | {| border="1" | ||
Revision as of 16:46, 16 July 2012
Camera Trig
Tune the beam for 15 MeV range, see the beam with camera. Get camera triggering.
Tune The Beam for 11-12 MeV
| Energy Switch | |
| Solenoid 1 | 3.0 A |
| Solenoid 2 | 5.2 A |
| Gun Hor | 0.1 A |
| Gun Ver | 0.1 A |
| Output Hor | -0.1 A |
| Output Ver | -0.3 A |
| Rep Rate | 10 |
| Gun HV | 10 (Knob Setting) |
| Gun Grid Voltage | 10(Knob Setting) |
| RF frequency | 2856.269 MHz |
| Modulator HV Power Supply | 4.13 (Knob Setting) |
| RF macro Pulse Length (FWHM) | 300 ns |
| Q1 (A) | 0 |
| Q2 (A) | 0 |
| Q3 (A) | 0 |
| Q4 (A) | 0 |
| Q5 (A) | 0 |
| Q6 (A) | 0 |