2-Neutron Correlation: Difference between revisions

From New IAC Wiki
Jump to navigation Jump to search
No edit summary
No edit summary
Line 35: Line 35:
** @ 1 meter from source => (<math>0.0198*\epsilon_0</math>) neutrons detected per pulse
** @ 1 meter from source => (<math>0.0198*\epsilon_0</math>) neutrons detected per pulse
** @ 70 cm from source => (<math>0.0379*\epsilon_0</math>) neutrons detected per pulse
** @ 70 cm from source => (<math>0.0379*\epsilon_0</math>) neutrons detected per pulse
[[File:DetEff_n_singlesrate.pdf | 400px]]


[https://wiki.iac.isu.edu/index.php/User:Jasenswanson Go Back]
[https://wiki.iac.isu.edu/index.php/User:Jasenswanson Go Back]

Revision as of 20:13, 31 May 2012

Big Detector Solid Angle Calculations

MCNPX Simulation
  • 14 MeV neutron source, emitted isotropically ([math]\displaystyle{ 4\pi }[/math])
  • Detector placed 1m away from source

  • face of the detector is 15.24cm x 76.2cm, and 3.6cm deep

The solid angle can be found from the number of particles hitting the detector as:
[math]\displaystyle{ \Delta \Omega = 4\pi*\frac{hits}{hits + misses} }[/math]

Results
  • Out of 1E9 neutrons generated, 8618287 neutrons hit the detector
    • [math]\displaystyle{ \Delta \Omega = 0.108 Sr }[/math]
      • if the detector is placed 70cm away from the source, [math]\displaystyle{ \Delta \Omega = 0.207 Sr }[/math]
  • As a test to verify our results
    • We change the detector size to 2cm by 2cm and used 1E9 neutrons again
    • 32061 neutrons struck the detector
    • [math]\displaystyle{ \Delta \Omega = 0.0004 Sr }[/math]
  • And, as a second test to verify our results
    • We change the detector size to 1cm by 1cm and used 1E9 neutrons again
    • 7965 neutrons struck the detector
    • [math]\displaystyle{ \Delta \Omega = 0.0001 Sr }[/math]
Now, what neutron singles rate into the detector should correspond to 1 fission per pulse?
  • If we have 1 fission per pulse and each fission emits on average 2.3 neutrons, we should expect 2.3 neutrons/pulse
  • The number of neutrons hitting the detector per pulse is found as [math]\displaystyle{ 2.3*\frac{\Delta \Omega}{4\pi} }[/math]
    • @ 1 meter => 0.0198 neutrons hitting the detector per pulse
    • @ 70 cm => 0.0379 neutrons hitting the detector per pulse
  • Taking into account the efficiency of the detector [math]\displaystyle{ \epsilon_0 }[/math], the number detected per pulse can be found as [math]\displaystyle{ 2.3*\frac{\Delta \Omega}{4\pi}*\epsilon_0 }[/math]
    • @ 1 meter from source => ([math]\displaystyle{ 0.0198*\epsilon_0 }[/math]) neutrons detected per pulse
    • @ 70 cm from source => ([math]\displaystyle{ 0.0379*\epsilon_0 }[/math]) neutrons detected per pulse

File:DetEff n singlesrate.pdf

Go Back