Big Detector Solid Angle Calculations
- MCNPX Simulation
- 14 MeV neutron source, emitted isotropically ([math]\displaystyle{ 4\pi }[/math])
- Detector placed 1m away from source
- face of the detector is 15.24cm x 76.2cm, and 3.6cm deep
- face of the detector is 15.24cm x 76.2cm, and 3.6cm deep
The solid angle can be found from the number of particles hitting the detector as:
[math]\displaystyle{ \Delta \Omega = 4\pi*\frac{hits}{hits + misses} }[/math]
- Results
- 1E9 Neutrons generated
- 8616290 neutrons hit the detector
- [math]\displaystyle{ \Delta \Omega = 0.116 Sr }[/math]
- As a test to verify our results
- We change the detector size to 1cm by 1cm and used 1E9 neutrons again
- 32061 neutrons struck the detector