2-Neutron Correlation: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
No edit summary |
||
| Line 2: | Line 2: | ||
MCNPX Simulation <br /> | MCNPX Simulation <br /> | ||
* 14 MeV neutron source, emitted isotropically (<math>4\pi</math>)<br /> | |||
* Detector placed 1m away from source<br /> | |||
** face of the detector is 15.24cm x 76.2cm, and 3.6cm deep<br /> | |||
The solid angle can be found as:<br /> | The solid angle can be found as:<br /> | ||
<math>\Delta \Omega = 4\pi*\frac{hits}{hits + misses}</math> | <math>\Delta \Omega = 4\pi*\frac{hits}{hits + misses}</math> | ||
Revision as of 17:17, 18 May 2012
Big Detector Solid Angle Calculations
MCNPX Simulation
- 14 MeV neutron source, emitted isotropically ([math]\displaystyle{ 4\pi }[/math])
- Detector placed 1m away from source
- face of the detector is 15.24cm x 76.2cm, and 3.6cm deep
- face of the detector is 15.24cm x 76.2cm, and 3.6cm deep
The solid angle can be found as:
[math]\displaystyle{ \Delta \Omega = 4\pi*\frac{hits}{hits + misses} }[/math]