Difference between revisions of "September 20, 2011"

From New IAC Wiki
Jump to navigation Jump to search
Line 95: Line 95:
 
|<span style="color:blue">'''2512'''</span>|| Down <br> 86A||In ||Open ||In ||Yes ||<span style="color:aqua">Out</span>||DU cylinder  
 
|<span style="color:blue">'''2512'''</span>|| Down <br> 86A||In ||Open ||In ||Yes ||<span style="color:aqua">Out</span>||DU cylinder  
 
|align="left"|<span style="color:blue">'''Long production run: 0 pulses (30 minute run)<br>'''</span>  
 
|align="left"|<span style="color:blue">'''Long production run: 0 pulses (30 minute run)<br>'''</span>  
 +
R(bottom) = 0 n/pulse ->  × 180 Hz × 60 sec/min =  <span style="color:aqua"> '''0 n/min'''</span><br>
 +
R(upstream) = 0 e+/pulse<br>
 +
|-
 +
|<span style="color:blue">'''2513'''</span>|| Down <br> 86A||In ||Open ||In ||Yes ||In ||<span style="color:tan">None</span>|align="left"|<span style="color:blue">'''Long production run: 0 pulses (30 minute run)<br>'''</span>
 
R(bottom) = 0 n/pulse ->  × 180 Hz × 60 sec/min =  <span style="color:aqua"> '''0 n/min'''</span><br>
 
R(bottom) = 0 n/pulse ->  × 180 Hz × 60 sec/min =  <span style="color:aqua"> '''0 n/min'''</span><br>
 
R(upstream) = 0 e+/pulse<br>
 
R(upstream) = 0 e+/pulse<br>

Revision as of 21:41, 20 September 2011

go back

summary what was been done

  • current 140 mA
  • pulse width 2 us
  • rep rate 180 Hz
  • E = 25 MeV


Run # Beam Dump magnet Collimator add coll Hardener 1" Al Radiator 25 um Al Target Comments
2502 Up
90A
In Open In Yes In DU cylinder Test radiator in/out.

120664 pulses
R(bottom) = 0.0012 n/pulse -> × 180 Hz × 60 sec/min = 12.9 n/min
R(upstream) = 0.0272 e+/pulse

2503 Up
90A
In Open In Yes Out DU cylinder Test radiator in/out.

121258 pulses
R(bottom) = 0 n/pulse
R(upstream) = 0.00091 e+/pulse
About 97% of photons are coming from the radiator according to PS. Very Good

2504 Down
86A
In Open In Yes In DU cylinder Test radiator in/out.

R(bottom) = 0.00137 n/pulse -> × 180 Hz × 60 sec/min = 14.8 n/min
R(upstream) = 0.0319 e+/pulse

2505 Down
86A
In Open In Yes Out DU cylinder Test radiator in/out.

122247 pulses
R(bottom) = 0 n/pulse
R(upstream) = 0.000908 e+/pulse
About 97% of photons are coming from the radiator according to PS. Very Good


Production runs

Run # Beam Dump magnet Collimator add coll Hardener 1" Al Radiator 25 um Al Target Comments
2506 Up
90A
In Open In Yes In DU cylinder Long production run: 972556 pulses (90 minute run)

Operator said the beam is really jittery
R(bottom) = 0.0013 n/pulse -> × 180 Hz × 60 sec/min = 14.0 n/min
R(upstream) = 0.0258 e+/pulse

2507 Down
86A
In Open In Yes In DU cylinder Long production run: 973769 pulses (90 minute run)

R(bottom) = 0.001298 n/pulse -> × 180 Hz × 60 sec/min = 14.0 n/min
R(upstream) = 0.0288 e+/pulse

2508 Down
86A
In Open In Yes Out DU cylinder Long production run: 300000 pulses (30 minute run)

R(bottom) = 6.6E-6 n/pulse -> × 180 Hz × 60 sec/min = 0.07 n/min
R(upstream) = 1.1E-3 e+/pulse

2509 Up
90A
In Open In Yes In DU cylinder Long production run: 200092 pulses (20 minute run)

R(bottom) = 9.7E-4 n/pulse -> × 180 Hz × 60 sec/min = 10.5 n/min
R(upstream) = 22.8E-3 e+/pulse

2510 Up
90A
In Open In Yes In DU cylinder Long production run: 766381 pulses (70 minute run)

R(bottom) = 9.8E-4 n/pulse -> × 180 Hz × 60 sec/min = 10.58 n/min
R(upstream) = 22.01E-3 e+/pulse

2511 Down
86A
In Open In Yes In DU cylinder Long production run: pulses (90 minute run)

R(bottom) = 0 n/pulse -> × 180 Hz × 60 sec/min = 0 n/min
R(upstream) = 0 e+/pulse

2512 Down
86A
In Open In Yes Out DU cylinder Long production run: 0 pulses (30 minute run)

R(bottom) = 0 n/pulse -> × 180 Hz × 60 sec/min = 0 n/min
R(upstream) = 0 e+/pulse

2513 Down
86A
In Open In Yes In align="left"|Long production run: 0 pulses (30 minute run)

R(bottom) = 0 n/pulse -> × 180 Hz × 60 sec/min = 0 n/min
R(upstream) = 0 e+/pulse


go up