Line 14: | Line 14: | ||
|2385||Up 2 mm||In ||Open ||Out||DU plate | |2385||Up 2 mm||In ||Open ||Out||DU plate | ||
|align="left"|Beam check-in run | |align="left"|Beam check-in run | ||
− | R(beam 45 left) = | + | R(beam 45 left) = 6/173553 = 0.0000346 n/pulse <br> |
− | R(beam 45 right) = | + | R(beam 45 right) = 0/583758 = 0.0 n/pulse<br> |
− | R(beam down) = | + | R(beam down) = 15/173553 = 0.0000864 n/pulse<br> |
− | R(upstream) = | + | R(upstream) = 1374/173553 = 0.00792 e+/pulse<br> |
+ | <span style="color:red">Beam was lost</span> | ||
+ | |- | ||
+ | |2386||Up 2 mm||In ||Open ||Out||DU plate | ||
+ | |align="left"|Beam check-in run | ||
+ | R(beam 45 left) = n/pulse <br> | ||
+ | R(beam 45 right) = n/pulse<br> | ||
+ | R(beam down) = n/pulse<br> | ||
+ | R(upstream) = e+/pulse<br> | ||
<span style="color:red">About 88% of photons are coming from the radiator. Good</span> | <span style="color:red">About 88% of photons are coming from the radiator. Good</span> | ||
|- | |- | ||
|} | |} |
Revision as of 14:53, 13 September 2011
summary what was been done
Run # | Beam | Dump magnet | Collimator | Radiator 10 um Al | Target | Comments |
---|---|---|---|---|---|---|
2385 | Up 2 mm | In | Open | Out | DU plate | Beam check-in run
R(beam 45 left) = 6/173553 = 0.0000346 n/pulse |
2386 | Up 2 mm | In | Open | Out | DU plate | Beam check-in run
R(beam 45 left) = n/pulse |