In quadrupole scan method, a quadrupole and a Yttrium Aluminum Garnet (YAG ) screen was used to measure emittance. Magnetic field strength of the quadrupole was changed in the process and corresponding beam shapes were observed on the screen. | In quadrupole scan method, a quadrupole and a Yttrium Aluminum Garnet (YAG ) screen was used to measure emittance. Magnetic field strength of the quadrupole was changed in the process and corresponding beam shapes were observed on the screen. | ||
Transfer matrix of a quadrupole magnet under thin lens approximation: | Transfer matrix of a quadrupole magnet under thin lens approximation: | ||
:<math> | |||
\left( \begin{matrix} 1 & 0 & 0 & 0 \\ 0 & -1 & 0 & 0 \\ 0 & 0 & -1 & 0 \\ 0 & 0 & 0 & -1 \end{matrix} \right) | |||
\left( \begin{matrix}V^0 \\ V^1 \\ V^2 \\ V^3 \end{matrix} \right) | |||
</math> | |||
== References == | == References == | ||
Revision as of 23:05, 21 August 2011
Emittance
What is Emittance
In accelerator physics, Cartesian coordinate system was used to describe motion of the accelerated particles. Usually the z-axis of Cartesian coordinate system is set to be along the electron beam line as longitudinal beam direction. X-axis is set to be horizontal and perpendicular to the longitudinal direction, as one of the transverse beam direction. Y-axis is set to be vertical and perpendicular to the longitudinal direction, as another transverse beam direction.
For the convenience of representation, we use [math]\displaystyle{ z }[/math] to represent our transverse coordinates, while discussing emittance. And we would like to express longitudinal beam direction with [math]\displaystyle{ s }[/math]. Our transverse beam profile changes along the beam line, it makes [math]\displaystyle{ z }[/math] is function of [math]\displaystyle{ s }[/math], [math]\displaystyle{ z~(s) }[/math]. The angle of a accelerated charge regarding the designed orbit can be defined as:
[math]\displaystyle{ z'=\frac{dz}{ds} }[/math]
If we plot [math]\displaystyle{ z }[/math] vs. [math]\displaystyle{ z' }[/math], we will get an ellipse. The area of the ellipse is an invariant, which is called Courant-Snyder invariant. The transverse emittance [math]\displaystyle{ \epsilon }[/math] of the beam is defined to be the area of the ellipse, which contains 90% of the particles <ref name="MConte08"> M. Conte and W. W. MacKay, “An Introduction To The Physics Of Particle Accelera tors”, World Scientifc, Singapore, 2008, 2nd Edition, pp. 257-330. </ref>.

Measurement of Emittance with Quad Scanning Method
In quadrupole scan method, a quadrupole and a Yttrium Aluminum Garnet (YAG ) screen was used to measure emittance. Magnetic field strength of the quadrupole was changed in the process and corresponding beam shapes were observed on the screen. Transfer matrix of a quadrupole magnet under thin lens approximation:
- [math]\displaystyle{ \left( \begin{matrix} 1 & 0 & 0 & 0 \\ 0 & -1 & 0 & 0 \\ 0 & 0 & -1 & 0 \\ 0 & 0 & 0 & -1 \end{matrix} \right) \left( \begin{matrix}V^0 \\ V^1 \\ V^2 \\ V^3 \end{matrix} \right) }[/math]
References
<references/>
Using APA reference style.
Go back: Positrons