Difference between revisions of "05/13/2011 coincidence test"
Jump to navigation
Jump to search
Line 36: | Line 36: | ||
|- | |- | ||
!PS1 | !PS1 | ||
− | | | + | |<math>2823\pm53.1</math>||20 min||<math>2.35\pm0.04</math> |
|- | |- | ||
!PS2 | !PS2 | ||
− | | | + | |<math>3091\pm55.6</math>||20 min||<math>2.57\pm0.05</math> |
|- | |- | ||
!PS1+PS2 | !PS1+PS2 | ||
− | | | + | |<math>93\pm9.6</math>||20 min||<math>(7.7\pm0.8)\cdot 10^{-2}</math> |
|} | |} | ||
Revision as of 22:01, 13 May 2011
Set up like that:
the distance between PS and n's PMT is abot 80 cm
The voltages and thresholds are as below. Note: I increased my thresholds for PS1 and PS2 from 80 mV up to 100 mV according to mu previous calibration threshold line.
PMT voltage, V | threshold, mV | discr. width, ns | |
---|---|---|---|
PS1 | -1500 | -80 | 100 |
PS1 | -1500 | -80 | 100 |
n's | -1500 | -200 | 10 |
Let's do first the coincidence test PS1+PS2
counts | time | counts/sec | |
---|---|---|---|
PS1 | 20 min | ||
PS2 | 20 min | ||
PS1+PS2 | 20 min |
The scope picture of PS1+PS2 coincidence event like: