Difference between revisions of "05/13/2011 coincidence test"

From New IAC Wiki
Jump to navigation Jump to search
Line 23: Line 23:
 
| -1500|| -200  
 
| -1500|| -200  
 
|}
 
|}
 
:▫ PS1 and PS2:  -1000 V
 
:▫ n's: -1500 V
 
 
The thresholds are:
 
:▫ PS1 and PS2:  -80 mV
 
:▫ n's: -200 mV
 
  
  
Line 40: Line 33:
 
|-
 
|-
 
!PS1
 
!PS1
|
+
|2823<math>/pm</math>||20 min||<math>/pm</math>
 
|-
 
|-
 
!PS2
 
!PS2
|
+
|3091<math>/pm</math>||20 min||<math>/pm</math>
 
|-
 
|-
 
!PS1+PS2  
 
!PS1+PS2  
|
+
|93<math>/pm</math>||20 min||<math>/pm</math>
 
|}
 
|}

Revision as of 21:40, 13 May 2011

Go Back

Set up like that:

Detector1.png

the distance between PS and n's PMT is abot 80 cm


The voltages and thresholds are as below. Note: I increased my thresholds for PS1 and PS2 from 80 mV up to 100 mV according to mu previous calibration threshold line.

PMT voltage, V threshold, mV
PS1 -1500 -80
PS1 -1500 -80
n's -1500 -200


Let's do first the coincidence test PS1+PS2

counts time counts/sec
PS1 2823[math]/pm[/math] 20 min [math]/pm[/math]
PS2 3091[math]/pm[/math] 20 min [math]/pm[/math]
PS1+PS2 93[math]/pm[/math] 20 min [math]/pm[/math]