HRRL 03-17-2011: Difference between revisions

From New IAC Wiki
Jump to navigation Jump to search
Setisadi (talk | contribs)
Setisadi (talk | contribs)
Line 89: Line 89:
[[File:HRRL 03-17-2011_Results_Q1_20mA_Pos_SupGau_X.png | 300 px]]
[[File:HRRL 03-17-2011_Results_Q1_20mA_Pos_SupGau_X.png | 300 px]]


emit=0.447 +- 0.001 mm*mrad, emit_norm=12.255 +- 0.040 mm*mrad


emit=0.231 +- 0.001 mm*mrad, emit_norm=6.334 +- 0.020 mm*mrad
beta=1.31512 +- 0.00000, alpha=1.0949 +-0.0007


beta=0.6619 +- 0.0000, alpha=0.0639 +-0.0003


[[File:HRRL 03-17-2011_Results_Q1_20mA_Pos_SupGau_Y.png | 300 px]]
[[File:HRRL 03-17-2011_Results_Q1_20mA_Pos_SupGau_Y.png | 300 px]]
Line 99: Line 99:
emit=0.231 +- 0.001 mm*mrad, emit_norm=6.334 +- 0.020 mm*mrad  
emit=0.231 +- 0.001 mm*mrad, emit_norm=6.334 +- 0.020 mm*mrad  


beta=0.661930 +- 0.000000, alpha=0.06386 +-0.00034  
beta=0.661930 +- 0.000000, alpha=0.06386 +-0.00034
 
 
 


=== 10 mA, Positive Current, X projection ===
=== 10 mA, Positive Current, X projection ===

Revision as of 04:12, 15 April 2011

Accelerator Tuning

Good Tune Used for good Scan

By Dr. Kim

Solenoid 1 6.8 A
Solenoid 2 10.4 A
Gun Ver -0.2 A
Gun Hor +0.4 A
Output Hor -1.4A
Output Ver -0.5 A
Gun HV +9.75 (Knob Setting)
Gun Grid Voltage 5.25 (Knob Setting)
RF frequency 2855.816 MHz
Modulator HV Power Supply 4.42 (Knob Setting)
RF macro Pulse Length (FWHM) 200 ns
Peak Current on FC 37.2 mAmps
Scope on FC
e- Beam Energy 14 MeV



Calibration

image OTR image cal_h (mm/px) cal_v (mm/px)
0.04308 0.04204
0.04320 0.04228
0.04349 0.04181
0.04323 0.04196
0.04337 0.04212
mean (mm/px) mean (mm/px)
[math]\displaystyle{ 0.04327 \pm 0.00016 }[/math] [math]\displaystyle{ 0.04204 \pm 0.00018 }[/math]


Results

Q1

At lower current background subtraction gets worse, because singal/noise drops.

42 mA, Positive Current, X projection

emit=0.389 +- 0.001 mm*mrad, emit_norm=10.658 +- 0.034 mm*mrad

beta=1.28826 +- 0.00004, alpha=0.9378 +-0.0007


42 mA, Negative Current, Y projection

emit=0.269 +- 0.001 mm*mrad, emit_norm=7.370 +- 0.024 mm*mrad

beta=0.9271 +- 0.0001, alpha=0.1922 +-0.0005


20 mA, Positive Current, X projection

emit=0.447 +- 0.001 mm*mrad, emit_norm=12.255 +- 0.040 mm*mrad

beta=1.31512 +- 0.00000, alpha=1.0949 +-0.0007



emit=0.231 +- 0.001 mm*mrad, emit_norm=6.334 +- 0.020 mm*mrad

beta=0.661930 +- 0.000000, alpha=0.06386 +-0.00034

10 mA, Positive Current, X projection

emit=0.489 +- 0.002 mm*mrad, emit_norm=13.408 +- 0.043 mm*mrad

beta=1.30289 +- 0.00000, alpha=1.1231 +-0.0007



emit=0.325 +- 0.001 mm*mrad, emit_norm=8.896 +- 0.029 mm*mrad

beta=1.319524 +- 0.000000, alpha=-0.05069 +-0.00069


5 mA, Positive Current, X projection

emit=0.556 +- 0.002 mm*mrad, emit_norm=15.230 +- 0.049 mm*mrad

beta=1.36924 +- 0.00000, alpha=1.1625 +-0.0007


emit=0.537 +- 0.002 mm*mrad, emit_norm=14.705 +- 0.047 mm*mrad

beta=1.859428 +- 0.000000, alpha=0.21834 +-0.00097


Q4

42 mA All Other Quads off

Haven't reach minimum.

42 mA Q1_at_-2A, Q2_at_+8A, Q3_at_-6A

x-projection:

emit=0.156 +- 0.001 mm*mrad, emit_norm=4.280 +- 0.014 mm*mrad

beta=0.75384 +- 0.00000, alpha=1.1587 +-0.0004


y-projection:

emit=0.110 +- 0.000 mm*mrad, emit_norm=3.000 +- 0.010 mm*mrad

beta=0.914334 +- 0.000000, alpha=-0.33329 +-0.00048


HRRL_Emittance_Measurements_March14-18-2011