HRRL 03-17-2011: Difference between revisions
Jump to navigation
Jump to search
| Line 87: | Line 87: | ||
[[File:HRRL 03-17-2011_Results_Q1_20mA_Pos_SupGau_X.png | 300 px]] | [[File:HRRL 03-17-2011_Results_Q1_20mA_Pos_SupGau_X.png | 300 px]] | ||
emit=0.231 +- 0.001 mm*mrad, emit_norm=6.334 +- 0.020 mm*mrad | |||
beta=0.6619 +- 0.0000, alpha=0.0639 +-0.0003 | |||
[[File:HRRL 03-17-2011_Results_Q1_20mA_Pos_SupGau_Y.png | 300 px]] | |||
emit=0.231 +- 0.001 mm*mrad, emit_norm=6.334 +- 0.020 mm*mrad | |||
beta=0.661930 +- 0.000000, alpha=0.06386 +-0.00034 | |||
[[HRRL_Emittance_Measurements_March14-18-2011]] | [[HRRL_Emittance_Measurements_March14-18-2011]] | ||
Revision as of 04:37, 14 April 2011
Accelerator Tuning
Good Tune Used for good Scan
By Dr. Kim
Calibration
Results
Q1
42 mA, Positive Current, X projection
emit=0.389 +- 0.001 mm*mrad, emit_norm=10.658 +- 0.034 mm*mrad
beta=1.28826 +- 0.00004, alpha=0.9378 +-0.0007
42 mA, Negative Current, Y projection
emit=0.269 +- 0.001 mm*mrad, emit_norm=7.370 +- 0.024 mm*mrad
beta=0.9271 +- 0.0001, alpha=0.1922 +-0.0005
20 mA, Positive Current, X projection
emit=0.231 +- 0.001 mm*mrad, emit_norm=6.334 +- 0.020 mm*mrad
beta=0.6619 +- 0.0000, alpha=0.0639 +-0.0003
emit=0.231 +- 0.001 mm*mrad, emit_norm=6.334 +- 0.020 mm*mrad
beta=0.661930 +- 0.000000, alpha=0.06386 +-0.00034