HRRL 03-18-2011: Difference between revisions

From New IAC Wiki
Jump to navigation Jump to search
Foretony (talk | contribs)
Setisadi (talk | contribs)
No edit summary
Line 1: Line 1:
=Tune parameters=
=Tune parameters=


Line 107: Line 105:


  Estimate the error in the above calibration
  Estimate the error in the above calibration
= Data Analysis =
== Preliminary results==
=== Gaussian fitted for whole image ===
12.74 MeV
Fitted Gaussian for whole image
x-projection:
emit=0.521 +- 0.013 mm*mrad, emit_norm=13.002 +- 0.330 mm*mrad
beta=0.884 +- 0.025, alpha=0.469 +-0.027
[[File:HRRL_03-18-2011_Data_Analysis_Preliminary_Results_Gauss_Fitted_Whole_Image.png]]
=== Gaussian fitted for part 1 of the image ===
Fitted Gaussian for part 1 of the image
        xl = 362;% center at 382
        xr = 404;
        yl = 241;% center at 271
        yr = 301;
xl: x left, xr: x right. yl: y left, yr: y right.
x-projection:
emit=0.322 +- 0.001 mm*mrad, emit_norm=8.022 +- 0.033 mm*mrad
beta=3.110 +- 0.003, alpha=0.906 +-0.002
[[File:HRRL_03-18-2011_Data_Analysis_Preliminary_Results_Gauss_Fitted_Part_1_Image.png]]
=== Gaussian fitted for part 2 of the image ===
Fitted Gaussian for part 2 of the image
        xl = 342;% center at 382
        xr = 424;
        yl = 241;% center at 271
        yr = 301;
x-projection:
emit=0.360 +- 0.001 mm*mrad, emit_norm=8.970 +- 0.031 mm*mrad
beta=1.993 +- 0.001, alpha=0.672 +-0.001
[[File:HRRL_03-18-2011_Data_Analysis_Preliminary_Results_Gauss_Fitted_Part_2_Image.png]]
=== Gaussian fitted for part 3 of the image ===
Fitted Gaussian for part 3 of the image
        xl = 342;% center at 382
        xr = 424;
        yl = 221;% center at 271
        yr = 321;
       
x-projection:
emit=0.360 +- 0.001 mm*mrad, emit_norm=8.970 +- 0.031 mm*mrad
beta=1.993 +- 0.001, alpha=0.672 +-0.001
[[File:HRRL_03-18-2011_Data_Analysis_Preliminary_Results_Gauss_Fitted_Part_3_Image.png]]
=== Gaussian fitted for part 4 of the image ===
Fitted Gaussian for part 4 of the image
        xl = 322;% center at 382
        xr = 444;
        yl = 221;% center at 271
        yr = 321;
x-projection:
emit=0.350 +- 0.001 mm*mrad, emit_norm=8.738 +- 0.032 mm*mrad
beta=1.344 +- 0.002, alpha=0.464 +-0.002
[[File:HRRL_03-18-2011_Data_Analysis_Preliminary_Results_Gauss_Fitted_Part_4_Image.png]]




[[HRRL_Emittance_Measurements_March14-18-2011]]
[[HRRL_Emittance_Measurements_March14-18-2011]]

Revision as of 18:52, 3 April 2011

Tune parameters

Previous Tune at the higher energy

Solenoid 1 5.4 A
Solenoid 2 5.5 A
Gun Ver -0.2 A
Gun Hor +0.4 A
Output Hor -0.5 A
Output Ver -0.5 A
Gun HV +9.75 (Knob Setting)
Gun Grid Voltage 5.25 (Knob Setting)
RF frequency 2855.813 MHz
Modulator HV Power Supply 4.11 (Knob Setting)
RF macro Pulse Length (FWHM) 200 ns

Solenoid comparison with yesterdays higher energy tune

V1 (Gun Vertical) H1 (Gun Horizontal) Sol1 (Gun Sol) V2 (Output Vertical) H2 (Output horizontal Sol 2 (Output solenoid) OTR Pict FC pict
(A) (A) (A) (A) (A) (A)
(-0.3) +0 0 0 -0 -0
(-0.2) +0.4 5.4 -0.5 -0.5 5.5
(-0.2) +0.4 6.8 -0.5 -0.5 5.5
(-0.2) +0.4 6.8 -0.5 -0.5 10.4

Quad Scans

To test reproducibility from yesterday. Scan at 40, 20, 10, 5 mA peak currents. Scan twice on each Current.

Do Energy Scan

Bend the beam through 45 bending dipole, take images on the scope of FC and YAG images.

D1 current Energy FC peak Volt Pic
(A) MeV mV
28 11.85 39
29 12.3 74
30 12.74 93
30.5 12.96 65
30.7 large uncertainty 22

Quad 1 Scan

Quad 1 OTR Pict FC pict
(A)
+0
+0.2
+0.4
+0.6
+0.8
+1.0
+1.2
+1.4
+1.6
+1.8
+2.0

Scan Quad 4

Calibration

Estimate the error in the above calibration


Data Analysis

Preliminary results

Gaussian fitted for whole image

12.74 MeV

Fitted Gaussian for whole image x-projection:

emit=0.521 +- 0.013 mm*mrad, emit_norm=13.002 +- 0.330 mm*mrad

beta=0.884 +- 0.025, alpha=0.469 +-0.027

Gaussian fitted for part 1 of the image

Fitted Gaussian for part 1 of the image

       xl = 362;% center at 382
       xr = 404;
       yl = 241;% center at 271
       yr = 301;
xl: x left, xr: x right. yl: y left, yr: y right.

x-projection:

emit=0.322 +- 0.001 mm*mrad, emit_norm=8.022 +- 0.033 mm*mrad

beta=3.110 +- 0.003, alpha=0.906 +-0.002


Gaussian fitted for part 2 of the image

Fitted Gaussian for part 2 of the image

       xl = 342;% center at 382
       xr = 424;
       yl = 241;% center at 271
       yr = 301;

x-projection:

emit=0.360 +- 0.001 mm*mrad, emit_norm=8.970 +- 0.031 mm*mrad

beta=1.993 +- 0.001, alpha=0.672 +-0.001



Gaussian fitted for part 3 of the image

Fitted Gaussian for part 3 of the image

       xl = 342;% center at 382
       xr = 424;
       yl = 221;% center at 271
       yr = 321;
       

x-projection:

emit=0.360 +- 0.001 mm*mrad, emit_norm=8.970 +- 0.031 mm*mrad

beta=1.993 +- 0.001, alpha=0.672 +-0.001



Gaussian fitted for part 4 of the image

Fitted Gaussian for part 4 of the image

       xl = 322;% center at 382
       xr = 444;
       yl = 221;% center at 271
       yr = 321;

x-projection:

emit=0.350 +- 0.001 mm*mrad, emit_norm=8.738 +- 0.032 mm*mrad

beta=1.344 +- 0.002, alpha=0.464 +-0.002




HRRL_Emittance_Measurements_March14-18-2011