Difference between revisions of "HRRL 03-18-2011"
Jump to navigation
Jump to search
Line 1: | Line 1: | ||
=Tune parameters= | =Tune parameters= | ||
+ | Previous Tune at the higher energy | ||
{| border="1" | {| border="1" | ||
− | | Solenoid 1 || | + | | Solenoid 1 || 5.4 A |
|- | |- | ||
− | |Solenoid 2 || | + | |Solenoid 2 || 5.5 A |
|- | |- | ||
|Gun Ver || -0.2 A | |Gun Ver || -0.2 A | ||
Line 24: | Line 25: | ||
|- | |- | ||
| RF macro Pulse Length (FWHM) || 200 ns | | RF macro Pulse Length (FWHM) || 200 ns | ||
+ | |} | ||
+ | |||
+ | Solenoid comparison with yesterdays higher energy tune | ||
+ | |||
+ | {| border="3" cellpadding="20" cellspacing="0" | ||
+ | |V1 (Gun Vertical)||H1 (Gun Horizontal)|| Sol1 (Gun Sol) || V2 (Output Vertical) || H2 (Output horizontal || Sol 2 (Output solenoid)|| OTR Pict || FC pict | ||
+ | |- | ||
+ | |(A)||(A) || (A) ||(A)||(A) || (A) || || | ||
|- | |- | ||
− | | | + | | (-0.3)||+0 || 0 ||0||-0 || -0 ||[[File:OTR_Q1Scan03182011_SterOff.png | 100 px]] ||[[File:FC_Q1Scan03182011_SterOff.png | 100 px]] |
|- | |- | ||
− | | | + | | (-0.2)||+0.4 || 5.4 ||-0.5||-0.5 || 5.5 ||[[File:OTR_Q1Scan03182011_SterOn.png | 100 px]] ||[[File:FC_Q1Scan03182011_SterOon.png | 100 px]] |
+ | |- | ||
+ | | (-0.2)||+0.4 || 6.8 ||-0.5||-0.5 || 5.5 ||[[File:OTR_Q1Scan03182011_1.png | 100 px]] ||[[File:FC_Q1Scan03182011_1.png | 100 px]] | ||
+ | |- | ||
+ | | (-0.2)||+0.4 || 6.8 ||-0.5||-0.5 || 10.4 ||[[File:OTR_Q1Scan03182011_2.png | 100 px]] ||[[File:FC_Q1Scan03182011_2.png | 100 px]] | ||
|- | |- | ||
− | |||
− | |||
− | |||
|} | |} | ||
Revision as of 17:52, 18 March 2011
Tune parameters
Previous Tune at the higher energy
Solenoid 1 | 5.4 A |
Solenoid 2 | 5.5 A |
Gun Ver | -0.2 A |
Gun Hor | +0.4 A |
Output Hor | -1.4A |
Output Ver | -0.5 A |
Gun HV | +9.75 (Knob Setting) |
Gun Grid Voltage | 5.25 (Knob Setting) |
RF frequency | 2855.813 MHz |
Modulator HV Power Supply | 4.11 (Knob Setting) |
RF macro Pulse Length (FWHM) | 200 ns |
Solenoid comparison with yesterdays higher energy tune
Quad Scans
To test reproducibility from yesterday. Scan at 40, 20, 10, 5 mA peak currents. Scan twice on each Current.
Do Energy Scan
Bend the beam through 45 bending dipole, take images on the scope of FC and YAG images.
D1 current | Energy | FC peak Volt | Pic |
(A) | MeV | mV | |
28 | 11.85 | 39 | |
29 | 12.3 | 74 | |
30 | 12.74 | 93 | |
30.5 | 12.96 | 65 | |
30.7 | large uncertainty | 22 |