Line 70: Line 70:
| (-0.2)||+0.4 || 6.8 ||-0.5||-0.5 || 5.5 ||[[File:OTR_Q1Scan03182011_1.png | 100 px]] ||[[File:FC_Q1Scan03182011_1.png | 100 px]]
| (-0.2)||+0.4 || 6.8 ||-0.5||-0.5 || 5.5 ||[[File:OTR_Q1Scan03182011_1.png | 100 px]] ||[[File:FC_Q1Scan03182011_1.png | 100 px]]
|-
|-
| (-0.2)||+0.4 || 6.8 ||-0.5||-0.5 || 10.5 ||[[File:OTR_Q1Scan03182011_1.png | 100 px]] ||[[File:FC_Q1Scan03182011_1.png | 100 px]]
| (-0.2)||+0.4 || 6.8 ||-0.5||-0.5 || 10.4 ||[[File:OTR_Q1Scan03182011_2.png | 100 px]] ||[[File:FC_Q1Scan03182011_2.png | 100 px]]
|-
|-
|}
|}

Revision as of 17:45, 18 March 2011

Tune parameters

Solenoid 1 6.8 A
Solenoid 2 10.4 A
Gun Ver -0.2 A
Gun Hor +0.4 A
Output Hor -1.4A
Output Ver -0.5 A
Gun HV +9.75 (Knob Setting)
Gun Grid Voltage 5.25 (Knob Setting)
RF frequency 2855.813 MHz
Modulator HV Power Supply 4.11 (Knob Setting)
RF macro Pulse Length (FWHM) 200 ns
Peak Current on FC 37.2 mAmps
Scope on FC
e- Beam Energy 14 MeV


Quad Scans

To test reproducibility from yesterday. Scan at 40, 20, 10, 5 mA peak currents. Scan twice on each Current.

Do Energy Scan

Bend the beam through 45 bending dipole, take images on the scope of FC and YAG images.

D1 current Energy FC peak Volt Pic
(A) MeV mV
28 11.85 39
29 12.3 74
30 12.74 93
30.5 12.96 65
30.7 large uncertainty 22

Quad 1 Scan

V1 (Gun Vertical) H1 (Gun Horizontal) Sol1 (Gun Sol) V2 (Output Vertical) H2 (Output horizontal Sol 2 (Output solenoid) OTR Pict FC pict
(A) (A) (A) (A) (A) (A)
(-0.3) +0 0 0 -0 -0
(-0.2) +0.4 5.4 -0.5 -0.5 5.5
(-0.2) +0.4 6.8 -0.5 -0.5 5.5
(-0.2) +0.4 6.8 -0.5 -0.5 10.4

Scan Quad 4

HRRL_Emittance_Measurements_March14-18-2011