Difference between revisions of "HRRL 03-18-2011"
Jump to navigation
Jump to search
Line 7: | Line 7: | ||
|D1 current||Energy || Charge | |D1 current||Energy || Charge | ||
|- | |- | ||
− | |(A)||MeV || mV | + | |(A)||MeV || mV ||FC scope pic |
|- | |- | ||
− | |28 ||11.85 || ||[[File:FC2_0318011_28A_11.85.png| 200 px]] | + | |28 ||11.85 ||39 ||[[File:FC2_0318011_28A_11.85.png| 200 px]] |
|- | |- | ||
− | |29 ||12.3 || ||[[File:FC2_0318011_28A_12.3.png| 200 px]] | + | |29 ||12.3 ||74 ||[[File:FC2_0318011_28A_12.3.png| 200 px]] |
|- | |- | ||
|30 || 12.74 || ||[[File:FC2_0318011_30A_12.74.png| 200 px]] | |30 || 12.74 || ||[[File:FC2_0318011_30A_12.74.png| 200 px]] |
Revision as of 16:55, 18 March 2011
Scan Qaud 1
To test reproducibility from yesterday. Scan at 40, 20, 10, 5 mA peak currents. Scan twice on each Current.
Do Energy Scan
Bend the beam through 45 bending dipole, take images on the scope of FC and YAG images.
D1 current | Energy | Charge | |
(A) | MeV | mV | FC scope pic |
28 | 11.85 | 39 | |
29 | 12.3 | 74 | |
30 | 12.74 | ||
30.5 | 12.96 |