Difference between revisions of "FC calibration (by view screen monitoring) 3/1/11"

From New IAC Wiki
Jump to navigation Jump to search
(Created page with '[https://wiki.iac.isu.edu/index.php/PhotoFission_with_Polarized_Photons_from_HRRL Go Back] 1000 px [https://wiki.iac.isu.edu/index.php/PhotoFiss…')
 
Line 2: Line 2:
  
  
[[File:FC Calibration.png | 1000 px]]
+
[[File:File:FC Calibration 3.1.11.png | 1000 px]]
 +
 
 +
Here are:
 +
 
 +
#red line is the fitting line for beam up
 +
#green line is the fitting line for beam down
 +
#green line is the fitting line for beam up and down
 +
 
 +
We can see that all three line is almost the same so we can use the fitting line for whole range of bending magnet which is
 +
 
 +
<math>x(cm)= 0.059 + 0.028\cdot I(Ampers)</math>
  
  
 
[https://wiki.iac.isu.edu/index.php/PhotoFission_with_Polarized_Photons_from_HRRL Go Back]
 
[https://wiki.iac.isu.edu/index.php/PhotoFission_with_Polarized_Photons_from_HRRL Go Back]

Revision as of 21:48, 1 March 2011

Go Back


1000 px

Here are:

  1. red line is the fitting line for beam up
  2. green line is the fitting line for beam down
  3. green line is the fitting line for beam up and down

We can see that all three line is almost the same so we can use the fitting line for whole range of bending magnet which is

[math]x(cm)= 0.059 + 0.028\cdot I(Ampers)[/math]


Go Back