Difference between revisions of "TF EIMLab6 Writeup"
Line 103: | Line 103: | ||
I measure the times constant by looking how long it take the 2 Volt pulse to rise to (1-e^{-1}) =1.26 V | I measure the times constant by looking how long it take the 2 Volt pulse to rise to (1-e^{-1}) =1.26 V | ||
− | :\tau = 60 \times 10^{-6} | + | :<math>\tau = 60 \times 10^{-6}</math> |
:<math>R = \tau/C = 60 \times 10^{-6} s/ 1.210 \times 10^{-6} F =49.6 \Omega</math> | :<math>R = \tau/C = 60 \times 10^{-6} s/ 1.210 \times 10^{-6} F =49.6 \Omega</math> |
Revision as of 20:33, 11 February 2011
Lab 6 Pulses and RC Filters
Differentiator
1.) Adjust the pulse generator to output square pulses which at
sec in time.Possible capacitors
Possible Resistors
- s
tek012
2.)Construct the circuit below selecting an RC combination such that RC 1/10
3.)Measure
and . Sketch a picture comparing and .4.) Change the pulse width such that
5.)Measure
and .Sketch a picture comparing and .6.) Change the pulse width such that
7.)Measure
.Sketch a picture comparing and .ms | ||
Questions
1.) What happens if the amplitude of
is doubled.2.) What happens if R is doubled and C is halved?
Integrator
Now repeat the above experiment with the resistor and capacitor swapped to form the low pass circuit below.
ms | ||
Pulse Sharpener
The goal of this section is to demonstrate how well the circuit below can sharpen an input pulse
1.) The first step is to create an input pulse which is rounded, similar to the output of the integrator circuit when RC = 10
. You can do this using a capacitor shorted across the output of the pulse generator. This will essential be coupled to the input impedance of the pulse generator and form a low pass circuit.As a result the input voltage is given as
where
- = impedance of the function generator at output which produces V_{in}
- = capacitor shorting the function generator output to ground (not shown in the above picture)
I measure the times constant by looking how long it take the 2 Volt pulse to rise to (1-e^{-1}) =1.26 V
2.) The output should be given by
where
3.) Make measurements of the rise time
and . The rise time is defined as the time it take the pulse to go from 10% of its max value to 90% of its max value.( 5 pnts.)4.) Compare the measurement of
to what you expected based on your measured values of , and .( 15 pnts.)Questions
1.) Qualitatify, why is
?( 10 pnts.)2.) How is
worse than ( 10 pnts.)