Difference between revisions of "Ribbon Cable Attenuation Measurements"

From New IAC Wiki
Jump to navigation Jump to search
Line 22: Line 22:
  
 
  <math>V_1</math> - without Ribbon Cable
 
  <math>V_1</math> - without Ribbon Cable
  <math>V_1</math> - with Ribbon Cable
+
  <math>V_2</math> - with Ribbon Cable
  
 
==Pictures==
 
==Pictures==

Revision as of 02:13, 19 January 2011

Go Back

Experimental Set Up

IMG 0358.JPG

Measurements

Pulse width [math]V_1[/math] [math]V_2[/math] Attenuation, % Comments
[math]100\ \mu s[/math] [math]5.0\ V[/math] [math]4.5\ V[/math] 10 %
[math]10\ \mu s[/math] [math]5.0\ V[/math] [math]4.2\ V[/math] 16 %
[math]1\ \mu s[/math] [math]5.0\ V[/math] [math]3.0\ V[/math] 40 % see pictures about pulse's shape change
[math]100\ ns[/math] [math]5.0\ V[/math] [math]2.8\ V[/math] 44 % see pictures about pulse's shape change
[math]30\ ns[/math] [math]4.0\ V[/math] [math]1.8\ V[/math] 55 % see pictures about pulse's shape change
[math]V_1[/math] - without Ribbon Cable
[math]V_2[/math] - with Ribbon Cable

Pictures

[math]1\ \mu s[/math] pulse without Ribbon Cable [math]1\ \mu s[/math] pulse with Ribbon Cable
1us before.JPG 1us after.JPG



[math]100\ ns[/math] pulse without Ribbon Cable [math]100\ ns[/math] pulse with Ribbon Cable
100ns before.JPG 100ns after.JPG



[math]30\ ns[/math] pulse without Ribbon Cable [math]30\ ns[/math] pulse with Ribbon Cable
30ns before.JPG 30ns after.JPG




Go Back