Difference between revisions of "Collimation geometry for different beam energies"
Jump to navigation
Jump to search
Line 1: | Line 1: | ||
[http://wiki.iac.isu.edu/index.php/PhotoFission_with_Polarized_Photons_from_HRRL Go Back] | [http://wiki.iac.isu.edu/index.php/PhotoFission_with_Polarized_Photons_from_HRRL Go Back] | ||
+ | |||
+ | [http://wiki.iac.isu.edu/index.php/PhotoFission_with_Polarized_Photons_from_HRRL Go Back] | ||
+ | |||
+ | =90<math>^o</math> exit port measurements= | ||
+ | |||
+ | [[File:exit_port1.png|800px]]<br><br> | ||
=Critical and Kicker angles= | =Critical and Kicker angles= | ||
− | [[File:Beam_up_down.png]]<br> | + | [[File:Beam_up_down.png|800px]]<br> |
<math>\Theta_C = \frac{m_ec^2}{E}</math> | <math>\Theta_C = \frac{m_ec^2}{E}</math> | ||
Line 12: | Line 18: | ||
= tan^{-1}\left(\frac{1}{\sqrt{2}}\ tan(\Theta_C)\right)</math><br> | = tan^{-1}\left(\frac{1}{\sqrt{2}}\ tan(\Theta_C)\right)</math><br> | ||
− | = | + | =General collimator setup= |
+ | |||
+ | [[File:minimum_energy_condition.png|800px]] | ||
+ | |||
+ | <math>AC = 286\cdot\tan(\Theta_K)\ cm</math><br> | ||
+ | <math>A_1C_1 = (286 +183)\cdot\tan(\Theta_K)\ cm</math> | ||
+ | |||
+ | <math>BD = 286\cdot\tan(\Theta_C/m)\ cm</math><br> | ||
+ | <math>B_1D_1 = (286 + 183)\cdot\tan(\Theta_C/m)\ cm</math><br> | ||
+ | |||
+ | <math>\alpha = \frac{A_1D_1 - AB}{183} = \frac{(A_1C_1 + C_1D_1/2) - (AC - B_1D_1/2)}{183}</math> | ||
+ | |||
+ | <math>FA = AB/\tan(\alpha)\ cm</math><br> | ||
+ | <math>GH = (286 - FA)\cdot\tan(\alpha)\ cm</math> | ||
+ | |||
+ | =Funny pictures...= | ||
+ | |||
+ | ==how it looks (<math> \Theta_c/2</math>, pipe 3")== | ||
+ | |||
+ | [[File:vacuum_pipe_collimator_0.335_2.png]]<br> | ||
+ | |||
+ | ==how it looks 1 (<math> \Theta_c/4</math>, pipe 3")== | ||
+ | |||
+ | [[File:vacuum_pipe_collimator_0.168_2.png]]<br> | ||
+ | |||
+ | ==how it looks 2 (<math> \Theta_c/4</math>, pipe 3")== | ||
+ | |||
+ | [[File:vacuum_pipe_collimator_168_1.png]]<br> | ||
+ | |||
+ | ==how it looks 4 (<math> \Theta_c/2</math>, pipe (2 1/2)" and then pipe 4")== | ||
+ | |||
+ | need to adjust to converter position | ||
+ | |||
+ | [[File:vacuum_pipe_collimator_335_4.png]]<br> | ||
+ | |||
+ | |||
+ | ==how it looks 5 (<math> \Theta_c/2</math>, box 3"x4" and then pipe 4")== | ||
+ | |||
+ | need to adjust to converter position | ||
+ | |||
+ | [[File:vacuum_pipe_collimator_335_5.png]]<br> | ||
+ | |||
+ | |||
− | [ | + | [http://wiki.iac.isu.edu/index.php/PhotoFission_with_Polarized_Photons_from_HRRL Go Back] |
=geometry calculation= | =geometry calculation= |
Revision as of 22:50, 20 June 2010
90 exit port measurements
Critical and Kicker angles
General collimator setup
Funny pictures...
how it looks ( , pipe 3")
how it looks 1 ( , pipe 3")
how it looks 2 ( , pipe 3")
how it looks 4 ( , pipe (2 1/2)" and then pipe 4")
need to adjust to converter position
how it looks 5 ( , box 3"x4" and then pipe 4")
need to adjust to converter position
geometry calculation
beam energy | collimator diameter | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
25 MeV | 4.13 cm | 6.78 cm | 2.92 cm | 4.79 cm | 9.18 cm > 8.73 cm | 75 cm | 7.49 cm > 5.08 cm | ||||
25 MeV | 4.13 cm | 6.78 cm | 1.95 cm | 3.20 cm | 8.37 cm < 8.73 cm | 111 cm | 4.99 cm < 5.08 cm | ||||
25 MeV | 4.13 cm | 6.78 cm | 1.46 cm | 2.40 cm | 7.98 cm < 8.73 cm | 136 cm | 3.74 cm < 5.08 cm | ||||
44 MeV | 2.35 cm | 3.85 cm | 1.66 cm | 2.72 cm | 5.21 cm < 8.73 cm | 75 cm | 4.26 cm < 5.08 cm | ||||
44 MeV | 2.35 cm | 3.85 cm | 1.11 cm | 1.82 cm | 4.76 cm < 8.73 cm | 111 cm | 2.84 cm < 5.08 cm | ||||
44 MeV | 2.35 cm | 3.85 cm | 0.83 cm | 1.36 cm | 4.53 cm < 8.73 cm | 136 cm | 2.13 cm < 5.08 cm |