Difference between revisions of "Counts Rate (44 MeV LINAC)"
Jump to navigation
Jump to search
| Line 47: | Line 47: | ||
==cross section== | ==cross section== | ||
| − | + | [[File:phofission_sigma_U238.png]] | |
| − | + | Photonuclear cross section for <math>^{238}U\ \ \sigma (\gamma , F) </math> | |
| + | |||
| + | in (10,20) MeV region the average cross section is: | ||
'''130 mb''' | '''130 mb''' | ||
Revision as of 03:48, 18 May 2010
LINAC parameters used in calculations
1) pulse width 50 ns
2) pulse current 50 A
3) repetition rate 300 Hz
4) energy 44 MeV
Number of electrons/sec on radiator
Number of photons/sec from radiator
bremsstrahlung
in (10,20) MeV region we have about
0.1 photons/electrons/MeV/r.l
radiation length
Titanium r.l. is 3.59 cm
take radiator thickness is
steps together...
Collimation factor
assume we collimate 4-6 % of total # of photons (Alex, GEANT calculation)
then, incident flux on target is
Number of neutrons/sec (yields)
cross section
Photonuclear cross section for
in (10,20) MeV region the average cross section is:
130 mb
target thickness,
Target thickness = 1 cm:
neutrons per fission
2.4 neutrons/fission
steps together...
Worst Case Isotropic Neutrons
Let's say we have:
radius detector = 1 cm
1 meter away
fractional solid angle = <= geometrical acceptance
finally we have
Therefore, this experiment is do able.