=LINAC parameters used in calculations=<br>
+
=Counts Rate Calculations=
 +
 
 +
==LINAC parameters used in calculations==
 
1) pulse width 50 ns <br>
 
1) pulse width 50 ns <br>
 
2) pulse current 100 A <br>
 
2) pulse current 100 A <br>

Revision as of 05:15, 15 May 2010

Go Back

Counts Rate Calculations

LINAC parameters used in calculations

1) pulse width 50 ns
2) pulse current 100 A
3) repetition rate 120 Hz
4) energy 44 MeV

number of electrons in 1 second

[math] 50ps \times 100A \times 120Hz \times \frac{1\cdot e^-}{1.6\cdot 10^{-19}C} = 0.375 \cdot 10^{13} \frac{e^-}{sec} [/math]

number of gammas in 1 second

[math]10^{-3} \frac{\gamma /MeV}{e^-/r.l.} \times 2 \cdot 10^{-4} r.l. \times 44 MeV \times 0.375 \cdot 10^{12} \frac{e^-}{sec}=0.3 \cdot 10^{7} \frac{\gamma}{sec}[/math]

number of neutrons in 1 second