Difference between revisions of "Plastic Scintillator Calculation"
Line 50: | Line 50: | ||
− | Probability of interaction <math>= ((\frac{NumCarbonAtoms}{cm^3} *(\sigma_{elec}C + \sigma_{nucleus}C)) + (\frac{NumCarbonAtoms}{cm^3} *(\sigma_{elec}H + \sigma_{nucleus}H)))*100%</math> | + | Probability of interaction per <math>cm^3 = ((\frac{NumCarbonAtoms}{cm^3} *(\sigma_{elec}C + \sigma_{nucleus}C)) + (\frac{NumCarbonAtoms}{cm^3} *(\sigma_{elec}H + \sigma_{nucleus}H)))*100%</math> |
Using this method of calculation for Rexon RP 200 yields a probability <math> = 0.5234%</math> | Using this method of calculation for Rexon RP 200 yields a probability <math> = 0.5234%</math> |
Revision as of 06:47, 5 February 2009
Below is the calculations done to determine the probability of pair production depending on thickness of the scintillator.
Molecules per
(NOTE: is just the density of the scintillator material and N[A] is Avogadro's number)Molecules per
Weighted cross-section
Probability of interaction (%)
All cross sections listed here are pair production cross-sections
For carbon
orFor carbon
orFor hydrogen
orFor hydrogen
orAvogadro's number
Molecular formula for PVT
Density of polyvinyl toluene (a common scintillator material) [1])
(NOTE: this value is from Rexon RP 200or is it [2] (TF)H/C = 11/10
For the sample calculation the thickness will be set to 1 cm just to get probability per cm
So entering all the numbers into the 4 initial equations gives the following answers:
Molecules per
Molecules per
Weighted cross-section
Probability of interaction (%)
Doing the same calculations using the Bicron BC 408 PVT with anthracene [3] for the material yields a probability of
A different way to calculate probability of interaction
I checked out a few of the physics material supply sites and most of them list with their products the amounts of each individual atom per
. Therefore there is a quicker way to calculate the probability of interaction which is listed below.
Probability of interaction per
Using this method of calculation for Rexon RP 200 yields a probability
Using this method for Bicron BC 408 yields a probabiltiy