TDC Calibration: Difference between revisions

From New IAC Wiki
Jump to navigation Jump to search
Oborn (talk | contribs)
Oborn (talk | contribs)
Line 30: Line 30:
[[Image:Old_calibration.jpg |500 px]]
[[Image:Old_calibration.jpg |500 px]]


The width of photon peak is about 10.3 ns.
The width of photon peak is about '''10.3 ns'''.


[[Image:New_calibration.jpg |500 px]]
[[Image:New_calibration.jpg |500 px]]


The width of photon peak is about
The width of photon peak is about '''32.3 ns'''.

Revision as of 04:31, 7 November 2008

We used:

-detector A to calibrate all the TDCs;

-LeCroy octal discriminator to produce standard negative pulses;

-passive delay line to calibrate TDCs in the region < 100 ns;

-delay amplifier TENNELEC TC215 to calibrate TDCs in the region > 250 ns;

Range of all three TDCs was set to 50nsx100.

ADC-TAC pair was chosen in such a way that we used during the experiment.

ORTEC TAC 567-02 and ADC 1D

ORTEC TAC 567-01 and ADC 1A

ORTEC TAC 566-01 and ADC 1C


Comparison of old and new calibration coefficients

The width of photon peak is about 10.3 ns.

The width of photon peak is about 32.3 ns.