Line 24: | Line 24: | ||
Detector C Asymmetry: First run = -12.69%; Second run = -9.16% | Detector C Asymmetry: First run = -12.69%; Second run = -9.16% | ||
− | [[Image:Four_detectors_asymmetry.jpg | | + | [[Image:Four_detectors_asymmetry.jpg | 400 px]] |
On the picture: 1D - timing spectrum taken by upper detector, 1C - timing spectrum taken by side detector, 1A - timing spectrum taken by side reference (being kept stationary) detector, 1B - NaI accelerator current monitor | On the picture: 1D - timing spectrum taken by upper detector, 1C - timing spectrum taken by side detector, 1A - timing spectrum taken by side reference (being kept stationary) detector, 1B - NaI accelerator current monitor | ||
[http://www.iac.isu.edu/mediawiki/index.php/October_Fission_HRRL_Measurements_2008 Go Back] | [http://www.iac.isu.edu/mediawiki/index.php/October_Fission_HRRL_Measurements_2008 Go Back] |
Revision as of 00:00, 18 October 2008
NaI detector in place and working (used to measure the gamma flash).
File:Gamma flash measurement from NaI det.JPG
Asymmetry was observed for
:
is the number of neutrons/sec seen by the detector when placed above the target.
is the number of neutrons/sec seen by the detector when placed to the side of the target.
is the number of neutrons/sec seen by the detector when placed above the target.
is the number of neutrons/sec seen by the detector when placed to the side of the target.
is the number of neutrons/sec seen by the reference detector with the target. (The reference detector is beside the place of the side detector.)
is the number of neutrons/sec seen by the reference detector with the target. (The reference detector is beside the place of the side detector.)
Detector A Asymmetry: First run = -20.27%; Second run = -19.84%
Detector C Asymmetry: First run = -12.69%; Second run = -9.16%
On the picture: 1D - timing spectrum taken by upper detector, 1C - timing spectrum taken by side detector, 1A - timing spectrum taken by side reference (being kept stationary) detector, 1B - NaI accelerator current monitor