Difference between revisions of "TGEMS"

From New IAC Wiki
Jump to navigation Jump to search
Line 7: Line 7:
 
[http://arxiv.org/abs/0707.2543][[Media:Development_of_Tracking_Detectors_with_industrially_produced_GEM_Foils.pdf]]<br>
 
[http://arxiv.org/abs/0707.2543][[Media:Development_of_Tracking_Detectors_with_industrially_produced_GEM_Foils.pdf]]<br>
  
:<math>V_{GEM} = 0.103 \times V_{Detector}</math><br>  
+
:::<math>V_{GEM} = 0.103 \times V_{Detector}</math><br>  
  
 
<math>V_{GEM}</math> is between ~[300V, 600V] for <math>CF_4</math> and for <math>Ar/CO_2</math> it is [200V, 370V];<br>
 
<math>V_{GEM}</math> is between ~[300V, 600V] for <math>CF_4</math> and for <math>Ar/CO_2</math> it is [200V, 370V];<br>

Revision as of 15:06, 14 September 2008

TGEMS : defined as GEM detector which use thick PCboard (0.4 mm thick) size GEM preamplifiers with hole diameters between 0.5 and 1 mm.

[1], Media:01352098.pdf

TGEM Detector HV setting

[2]Media:Development_of_Tracking_Detectors_with_industrially_produced_GEM_Foils.pdf

[math]V_{GEM} = 0.103 \times V_{Detector}[/math]

[math]V_{GEM}[/math] is between ~[300V, 600V] for [math]CF_4[/math] and for [math]Ar/CO_2[/math] it is [200V, 370V];

[math]V_{Detector}[/math] voltage is ~[2900V, 5800V] ([1950V, 4000V]) for [math]CF_4[/math] ([math]Ar/CO_2[/math]).

TGEM detector.jpgTGEM detector 1.jpg

PCboard spacing = 1.5 - 2 mm.

Go back