Difference between revisions of "TGEMS"
Jump to navigation
Jump to search
Line 4: | Line 4: | ||
=TGEM Detector HV setting= | =TGEM Detector HV setting= | ||
+ | |||
[http://arxiv.org/abs/0707.2543][[Media:Development_of_Tracking_Detectors_with_industrially_produced_GEM_Foils.pdf]]<br> | [http://arxiv.org/abs/0707.2543][[Media:Development_of_Tracking_Detectors_with_industrially_produced_GEM_Foils.pdf]]<br> | ||
<math>V_{GEM} = 0.103 \times V_{Detector}</math><br> . | <math>V_{GEM} = 0.103 \times V_{Detector}</math><br> . | ||
+ | |||
+ | <math>V_{GEM}</math> is between ~[300V, 600V] for <math>CF_4</math> and for <math>Ar/CO_2</math> it is [200V, 370V];<br> | ||
+ | <math>V_{Detector}</math> - | ||
[[Image:TGEM_detector.jpg|300px]][[Image:TGEM_detector_1.jpg|300px]] | [[Image:TGEM_detector.jpg|300px]][[Image:TGEM_detector_1.jpg|300px]] |
Revision as of 14:58, 14 September 2008
TGEMS : defined as GEM detector which use thick PCboard (0.4 mm thick) size GEM preamplifiers with hole diameters between 0.5 and 1 mm.
TGEM Detector HV setting
[2]Media:Development_of_Tracking_Detectors_with_industrially_produced_GEM_Foils.pdf
.
-
PCboard spacing = 1.5 - 2 mm.