=TGEM Detector HV setting=
[http://arxiv.org/abs/0707.2543][[Media:Development_of_Tracking_Detectors_with_industrially_produced_GEM_Foils.pdf]]<br>
[http://arxiv.org/abs/0707.2543][[Media:Development_of_Tracking_Detectors_with_industrially_produced_GEM_Foils.pdf]]<br>
<math>V_{GEM} = 0.103 \times V_{Detector}</math><br> .
<math>V_{GEM} = 0.103 \times V_{Detector}</math><br> .
<math>V_{GEM}</math> is between ~[300V, 600V] for <math>CF_4</math> and for <math>Ar/CO_2</math> it is [200V, 370V];<br>
<math>V_{Detector}</math> -


[[Image:TGEM_detector.jpg|300px]][[Image:TGEM_detector_1.jpg|300px]]
[[Image:TGEM_detector.jpg|300px]][[Image:TGEM_detector_1.jpg|300px]]

Revision as of 14:58, 14 September 2008

TGEMS : defined as GEM detector which use thick PCboard (0.4 mm thick) size GEM preamplifiers with hole diameters between 0.5 and 1 mm.

[1], Media:01352098.pdf

TGEM Detector HV setting

[2]Media:Development_of_Tracking_Detectors_with_industrially_produced_GEM_Foils.pdf
[math]\displaystyle{ V_{GEM} = 0.103 \times V_{Detector} }[/math]
.

[math]\displaystyle{ V_{GEM} }[/math] is between ~[300V, 600V] for [math]\displaystyle{ CF_4 }[/math] and for [math]\displaystyle{ Ar/CO_2 }[/math] it is [200V, 370V];
[math]\displaystyle{ V_{Detector} }[/math] -

PCboard spacing = 1.5 - 2 mm.