TGEMS: Difference between revisions

From New IAC Wiki
Jump to navigation Jump to search
Oborn (talk | contribs)
No edit summary
Oborn (talk | contribs)
No edit summary
Line 3: Line 3:
[http://ieeexplore.ieee.org/xpls/abs_all.jsp?arnumber=1352098], [[Media:01352098.pdf]] <br>
[http://ieeexplore.ieee.org/xpls/abs_all.jsp?arnumber=1352098], [[Media:01352098.pdf]] <br>


=TGEM Detector HV setting=
[http://arxiv.org/abs/0707.2543][[Media:Development_of_Tracking_Detectors_with_industrially_produced_GEM_Foils.pdf]]<br>
[http://arxiv.org/abs/0707.2543][[Media:Development_of_Tracking_Detectors_with_industrially_produced_GEM_Foils.pdf]]<br>
 
<math>V_{GEM} = 0.103 \times V_{Detector}</math><br> .


[[Image:TGEM_detector.jpg|300px]][[Image:TGEM_detector_1.jpg|300px]]
[[Image:TGEM_detector.jpg|300px]][[Image:TGEM_detector_1.jpg|300px]]

Revision as of 14:51, 14 September 2008

TGEMS : defined as GEM detector which use thick PCboard (0.4 mm thick) size GEM preamplifiers with hole diameters between 0.5 and 1 mm.

[1], Media:01352098.pdf

TGEM Detector HV setting

[2]Media:Development_of_Tracking_Detectors_with_industrially_produced_GEM_Foils.pdf
[math]\displaystyle{ V_{GEM} = 0.103 \times V_{Detector} }[/math]
.

PCboard spacing = 1.5 - 2 mm.

Go back