Matching Detectors: Difference between revisions

From New IAC Wiki
Jump to navigation Jump to search
Oborn (talk | contribs)
Oborn (talk | contribs)
No edit summary
Line 1: Line 1:
=Detector C=
=Detector C=


Threshold at 80 mV.
==Threshold at 80 mV==


{| border="1" cellpadding="20" cellspacing="0"
{| border="1" cellpadding="20" cellspacing="0"
Line 41: Line 41:
|2100 || 14739
|2100 || 14739
|}<br>
|}<br>
==Threshold at 150 mV==
{| border="1" cellpadding="20" cellspacing="0"
|-
|High Voltage (Volts)
|Counts/5min
|-
|1500 || 173
|-
|1550||
|-
|1600 ||
|-
|1650 ||
|-
|1700 ||
|-
|1750||
|-
|1800 ||
|-
|1850 ||
|-
|1900 ||
|}




Line 47: Line 76:




Threshold at 80 mV
==Threshold at 80 mV==


{| border="1" cellpadding="20" cellspacing="0"
{| border="1" cellpadding="20" cellspacing="0"

Revision as of 16:16, 11 August 2008

Detector C

Threshold at 80 mV

High Voltage (Volts) Counts/5min
1500 563
1550 949
1600 1912
1650 3191
1700 4557
1750 6235
1800 7900
1850 9789
1900 12192


High Voltage (Volts) Counts/1min
2000 4444
2100 14739



Threshold at 150 mV

High Voltage (Volts) Counts/5min
1500 173
1550
1600
1650
1700
1750
1800
1850
1900


Detector B

Threshold at 80 mV

High Voltage (Volts) Counts/5min
1500 290
1550 316
1600 350
1650 470
1750 1267


High Voltage (Volts) Counts/1min
1850 671
1950 1197
1900 1167
2050