Difference between revisions of "HRRL Simulations"
Jump to navigation
Jump to search
| Line 16: | Line 16: | ||
[[Image:HRRL_ExperimentCell_World_1.jpg | 200 px]] | [[Image:HRRL_ExperimentCell_World_1.jpg | 200 px]] | ||
| − | I then ran 1 million events with the physics processes | + | I then ran 1 million events in which an incident 7 MeV electron hit the 2 mm thick Tungsten with the physics processes |
if (particleName == "gamma") { | if (particleName == "gamma") { | ||
Revision as of 11:28, 11 July 2008
This document describes the simulations performed to estimate the radiological background in the event that a 1 nA electron current from the HRRL enters the experimental cell.
Radiation monitors: Ludlum Model 45-8.
Low energy gamma cutoff = 60 keV
Tungsten SImulation
I created a world volume filled with Air to represent the experimental cell.
I created a 2mm thick tungsten target that is 30 cm x 30 cm in area.
The image below shows several electrons hitting the tungsten foil, then scattering in air. The red lines are electrons and the green ones are photons.
I then ran 1 million events in which an incident 7 MeV electron hit the 2 mm thick Tungsten with the physics processes
if (particleName == "gamma") {
// gamma
pmanager->AddDiscreteProcess(new G4PhotoElectricEffect);
pmanager->AddDiscreteProcess(new G4ComptonScattering);
pmanager->AddDiscreteProcess(new G4GammaConversion);
} else if (particleName == "e-") {
//electron
pmanager->AddProcess(new G4MultipleScattering,-1, 1,1);
pmanager->AddProcess(new G4eIonisation, -1, 2,2);
pmanager->AddProcess(new G4eBremsstrahlung, -1, 3,3);
I only kept event in which had a momentum component towards the ceiling