Difference between revisions of "5-19-08"
Jump to navigation
Jump to search
Line 86: | Line 86: | ||
{| border="1" cellpadding="20" cellspacing="0" | {| border="1" cellpadding="20" cellspacing="0" | ||
|- | |- | ||
− | | | + | Measurement |
− | + | |Turns | |
+ | |h (cm) | ||
|- | |- | ||
− | | | + | | Original position || 10.02 |
|- | |- | ||
− | | | + | | 10 turns ccw (down) || 9.03 |
|- | |- | ||
− | | 10 || | + | | 10 turns ccw (down) || 7.00 |
|- | |- | ||
− | | | + | | 10 turns cw (up) || 9.04 |
|- | |- | ||
− | | | + | | 10 turns cw (up) || 10.04 |
|- | |- | ||
− | | | + | | 10 turns ccw (down) || 9.05 |
+ | |- | ||
+ | | 10 turns ccw (down) || 7.00 | ||
+ | |- | ||
+ | | 10 turns ccw (down) || 4.94 | ||
|- | |- | ||
|}<br> | |}<br> |
Revision as of 12:30, 20 May 2008
Tests of the beam position monitor and the FC using the HRRL
Position tests
Below we see the first signals from the BPM
changed current
Current | scope picture |
80(early) | |
40 | |
80(later) |
changed position
counter clockwise 1 turn
FC performance
Current (mA) | scope picture |
0 | File:Put picture here |
1 | File:Put picture here |
10 | |
30 | |
60 | |
80 |
Rise of table per rotation
MeasurementTurns | h (cm) |
Original position | 10.02 |
10 turns ccw (down) | 9.03 |
10 turns ccw (down) | 7.00 |
10 turns cw (up) | 9.04 |
10 turns cw (up) | 10.04 |
10 turns ccw (down) | 9.05 |
10 turns ccw (down) | 7.00 |
10 turns ccw (down) | 4.94 |