Difference between revisions of "PbF2 CrystalNumber33"
Jump to navigation
Jump to search
Line 1: | Line 1: | ||
Below are the resulting transparency measurements for PbF2 block # 33 | Below are the resulting transparency measurements for PbF2 block # 33 | ||
=12/4/07= | =12/4/07= | ||
+ | ;Accelerator Settings | ||
+ | {| border="1" | ||
+ | | beam energy || 20 MeV | ||
+ | |- | ||
+ | | Rep Rate: || 30 Hz | ||
+ | |- | ||
+ | | I_peak: || 60 mA/pulse | ||
+ | |- | ||
+ | | pulse width:|| 0.1 <math>\mu</math>s (100 ns) | ||
+ | |- | ||
+ | |beam start: || 13:09 | ||
+ | |- | ||
+ | |beam stop: || | ||
+ | |} | ||
+ | |||
+ | ;Pick-up Coil Pulse Recording (PbF2 crystal at z=30cm away) | ||
+ | |||
+ | O-scope pulses were recorded on the pick-up coil with dimensions in inches and the intensity measured in Volt <math>\times</math> ns | ||
=12/5/07= | =12/5/07= |
Revision as of 20:54, 4 December 2007
Below are the resulting transparency measurements for PbF2 block # 33
12/4/07
- Accelerator Settings
beam energy | 20 MeV |
Rep Rate: | 30 Hz |
I_peak: | 60 mA/pulse |
pulse width: | 0.1 | s (100 ns)
beam start: | 13:09 |
beam stop: |
- Pick-up Coil Pulse Recording (PbF2 crystal at z=30cm away)
O-scope pulses were recorded on the pick-up coil with dimensions in inches and the intensity measured in Volt
ns