Difference between revisions of "PbF2 CrystalNumber16"
Jump to navigation
Jump to search
Line 58: | Line 58: | ||
=12/4/07= | =12/4/07= | ||
+ | |||
+ | Dose rate measurements (@0957 hours) | ||
+ | |||
+ | [[Image:Block16.JPG | 500 px]] [[Image:Block1690deg.JPG | 500 px]] | ||
+ | |||
+ | Under Blue light for 19 hours before next irradiation. | ||
=12/5/07= | =12/5/07= |
Revision as of 17:18, 5 December 2007
Below are the resulting transparency measurements for PbF2 block # 16
12/3/07
- Accelerator Settings
beam energy | 20 MeV |
Rep Rate: | 30 Hz |
I_peak: | 60 mA/pulse |
pulse width: | 0.1 | s (100 ns)
beam start: | 15:39 |
beam stop: | 16:39 |
- Pick-up Coil Pulse Recording (PbF2 crystal at z=30cm away)
O-scope pulses were recorded on the pick-up coil with dimensions in inches and the intensity measured in Volt
ns- Dose rate measurements (@1643 hours)
-radiation | 3.5 mR/hr |
-radiation: | 12 mR/hr |
- Dose rate measurements (@1532 hours)
-radiation | 3 mR/hr |
-radiation: | 7 mR/hr |
12/4/07
Dose rate measurements (@0957 hours)
Under Blue light for 19 hours before next irradiation.
12/5/07
- Accelerator Settings
beam energy | 20 MeV |
Rep Rate: | 30 Hz |
I_peak: | 60 mA/pulse |
pulse width: | 0.1 | s (100 ns)
beam start: | 08:38 |
beam stop: |
- Pick-up Coil Pulse Recording (PbF2 crystal at z=30cm away)
O-scope pulses were recorded on the pick-up coil with dimensions in inches and the intensity measured in Volt
ns