Below are the resulting transparency measurements for PbF2 block # 16

12/3/07

Accelerator Settings
beam energy 20 MeV
Rep Rate: 30 Hz
I_peak: 60 mA/pulse
pulse width: 0.1 [math]\mu[/math]s (100 ns)
beam start: 15:39
beam stop:
Pick-up Coil Pulse Recording of PbF2 crystal at z=30cm

O-scope pulses were recorded on the pick-up coil with dimensions in inches and the intensity measured in Volt [math]\times[/math] ns

@16:00 PbF2 Crystal 16 Z-30cm 4pm.jpg


PbF2 FineeScan Z-15cm.jpg

12/4/07

12/5/07