PbF2 CrystalNumber16: Difference between revisions

From New IAC Wiki
Jump to navigation Jump to search
Oborn (talk | contribs)
Oborn (talk | contribs)
Line 1: Line 1:
Below are the resulting transparency measurements for PbF2 block # 16
Below are the resulting transparency measurements for PbF2 block # 16
=12/3/07=
=12/3/07=
Beam Energy= 20MeV
;Accelerator Settings
Frequency= 30Hz
{| border="1"
Current= 60mA
| beam energy || 20 MeV
Pulse Width=100ns
|-
Beam Start= 15:39
| Rep Rate: ||  30 Hz
Beam Stop=
|-
| I_peak:    || 60 mA/pulse
|-
| pulse width:|| 0.1 <math>\mu</math>s (100 ns)
|-
|beam start: || 15:39
|-
|beam stop: ||
|}


=12/4/07=
=12/4/07=

Revision as of 22:51, 3 December 2007

Below are the resulting transparency measurements for PbF2 block # 16

12/3/07

Accelerator Settings
beam energy 20 MeV
Rep Rate: 30 Hz
I_peak: 60 mA/pulse
pulse width: 0.1 [math]\displaystyle{ \mu }[/math]s (100 ns)
beam start: 15:39
beam stop:

12/4/07

12/5/07

Go Back