− | Beam spot size mapping in ''x'' and ''y'' with the Faraday Cup (FC) for ''z'' = 30cm from Window. We will move the table in or out depending on whether the beam spot size is greater or smaller than 2.0 cm. Translator table positioned in z. | + | Beam spot size mapping in ''x'' and ''y'' with the Faraday Cup (FC) for ''z'' = 30cm from Window. |
+ | We will move the table in or out depending on whether the beam spot size is greater or smaller than 2.0 cm. | ||
+ | Translator table positioned in z. | ||
Linearity tests of the pickup coil and FC. We will just change the width of the pulse 80 ns, 100 ns, 200 ns, 250 us. | Linearity tests of the pickup coil and FC. We will just change the width of the pulse 80 ns, 100 ns, 200 ns, 250 us. |
Revision as of 19:06, 20 November 2007
Day 1. December 3, 2007.
Glass Slides at 10 cm, 30 cm, and 50 cm.
Beam spot size mapping in x and y with the Faraday Cup (FC) for z = 30cm from Window.
We will move the table in or out depending on whether the beam spot size is greater or smaller than 2.0 cm. Translator table positioned in z.
Linearity tests of the pickup coil and FC. We will just change the width of the pulse 80 ns, 100 ns, 200 ns, 250 us.
500 ns, 1 us 1.25 us.
Run
o Day 1: 5 hours of beamtime
1a) a first irradiation(blocks 1~4) ~5 hours Day 1 2a) do a transparency measurement (blocks 1~4) ~3 hours Day 1 3a) do a block (blocks 1~4) curing exposure to a blue light 24 hours day
1 day o Day 2: 5 hours of beamtime