[http://www.slac.stanford.edu/grp/lcls/controls/global/standards/hardware/v6100a_ih.pdf Information below is Table 5-11 pg 92 of this reference] | [http://www.slac.stanford.edu/grp/lcls/controls/global/standards/hardware/v6100a_ih.pdf Information below is Table 5-11 pg 92 of this reference] | ||
{| border="1" | {| border="1" | ||
− | | ROC Pin# || DB9 Pin # || Signal | + | | ROC Pin# || DB9 Pin # || DB9 shell || Signal |
|- | |- | ||
− | | 1 || 1 || DCD (Carrier Detect) | + | | 1 || 1 || Blue || DCD (Carrier Detect) |
|- | |- | ||
− | | 2 || 7 || RTS (Request to Send) | + | | 2 || 7 || Orange || RTS (Request to Send) |
|- | |- | ||
− | | 3 || 5 || GNDC | + | | 3 || 5 || Black || GNDC |
|- | |- | ||
− | | 4 || 3 || TX (Transmit) | + | | 4 || 3 || Red || TX (Transmit) |
|- | |- | ||
− | | 5 || 2 || RX (Recieve) | + | | 5 || 2 || Green || RX (Recieve) |
|- | |- | ||
− | | 6 || 5 || GNDC | + | | 6 || 5 || Yellow || GNDC |
|- | |- | ||
− | | 7 || 8 || CTS (Clear to Send) | + | | 7 || 8 || Brown || CTS (Clear to Send) |
|- | |- | ||
− | | 8 || 4 || DTR (Data Terminal Ready) | + | | 8 || 4 || White || DTR (Data Terminal Ready) |
|} | |} | ||
Revision as of 02:17, 15 August 2007
MVME 6100
ROC1 ethernet address: 0001AF1998B5
ROC1 ethernet address: 0001AF1998B6
MPC7457 RISC G4 processor (PPC family)
Debug Connector Pinouts
Information below is Table 5-11 pg 92 of this reference
ROC Pin# | DB9 Pin # | DB9 shell | Signal |
1 | 1 | Blue | DCD (Carrier Detect) |
2 | 7 | Orange | RTS (Request to Send) |
3 | 5 | Black | GNDC |
4 | 3 | Red | TX (Transmit) |
5 | 2 | Green | RX (Recieve) |
6 | 5 | Yellow | GNDC |
7 | 8 | Brown | CTS (Clear to Send) |
8 | 4 | White | DTR (Data Terminal Ready) |
Basic commands
setting the time
The command below will print the help screen for the time set command
he set
for example
MVME6100> set -t082604163100
MVME6100> time
THU AUG 26 16:31:02.00 2004
show the flash memory
MVME6100> flashShow
Load in the VxWorks boot kernel
MVME6100> tftpGet -cCLIENT_IP_ADDRESS -sSERVER_IP_ADDRESS -fFILENAME
CLIENT_IP_ADDESS is the address to send the file to SERVER_IP_ADDRESS is the address of the computer hosting the file
Flash the RAM with the program
>MVME6100>flashProgram -d/dev/flash0 -o03f00100 -nfff00
After flashing you flip dipwsitch #2 on S4 fo off and powercycle