July 6, 2007 Neutron Capture in lead: Difference between revisions

From New IAC Wiki
Jump to navigation Jump to search
Oborn (talk | contribs)
No edit summary
Oborn (talk | contribs)
Line 10: Line 10:
For energy line 803 keV    ( # of counts without lead / # of count with  lead ) =0.5
For energy line 803 keV    ( # of counts without lead / # of count with  lead ) =0.5


[[http://arxiv.org/abs/0707.3679 (n,<math>\gamma) from Pb-206 from 1 ev to 600 keV</math>
[[http://arxiv.org/abs/0707.3679 (n,<math>\gamma) from Pb-206 from 1 ev to 600 keV</math>]]

Revision as of 14:19, 26 July 2007

Paraffin wax layer of thickness 12.6 cm was used as a neutron attenuator and for cosmic rays lead of thickness 10 cm on sides of HpGe detector. The source was Cf-252 without and with lead container of 60μCi activity.

1. Energy Region 100-500 keV

2. Energy Region 500-900 keV


We have sharp peak on 803 keV, which is the result of the lead container. This line coressponds to thermal-neutron capture in lead Pb-206.[1]. However, 388 kev and 333 kev, energy lines of Cf-249 are more dominant without lead.
For energy line 803 keV ( # of counts without lead / # of count with lead ) =0.5

[(n,[math]\displaystyle{ \gamma) from Pb-206 from 1 ev to 600 keV }[/math]]