Poly box to contain Cf-252 source for attenuation measurements
He3 tube mounting for attenuation measurements
He3 tube mounted on 2" of virgin poly for attenuation measurements
Full poly box with lid pulled back for easy insertion of Cf-252 source
Top down view of Cf-252 source in place, ready to be covered by top sheet of virgin poly
Full setup with 8.5" of purple borated poly in place
He3 tube is mounted on 2" of virgin poly to put it at rough center of californium source
Cf252 source is enclosed in thermalizing virgin poly box
He3 tube is 8.5" from outside face of thermalizer
Cf252 is mounted approximately .5" behind thermalizing poly plate
Thermalizing poly plate is 1" thick
Will upload pictures and attached comments to each picture
Measurements
Background Measurements
1250V Source Out Data
Run Number
Configuration
Discriminator Threshold (mV)
Cf-252 Button Source
Counts
Run Time (Sec)
Count Rate (Hz)
Uncertainty
1
Detector on poly at +1250V
255
No
32
300
0.107
0.019
2
Detector on poly at +1250V
255
No
44
300
0.147
0.022
3
Detector on poly at +1250V
255
No
55
300
0.183
0.025
4
Detector on poly at +1250V
255
No
34
300
0.113
0.019
5
Detector on poly at +1250V
255
No
20
300
0.067
0.015
Source In
1250V Source In
Run Number
Configuration
Discriminator Threshold (mV)
Cf-252 Button Source
Counts
Run Time (Sec)
Count Rate (Hz)
Uncertainty
1
Detector on poly at +1250V
255
Yes
11255
300
2
Detector on poly at +1250V
255
Yes
10996
300
3
Detector on poly at +1250V
255
Yes
10750
300
4
Detector on poly at +1250V
255
Yes
10815
300
5
Detector on poly at +1250V
255
Yes
10696
300
Purple Poly without Thermalizer
For some reason, the purple poly bricks are 1 1/8" thick
1" Purple poly, no thermalizer
1250V source in
Run Number
Configuration
Discriminator Threshold (mV)
Cf-252 Button Source
Counts
Run Time (Sec)
Count Rate (Hz)
Uncertainty
1
Detector on poly at +1250V
255
Yes
2816
300
9.39
0.177
2
Detector on poly at +1250V
255
Yes
2809
300
9.36
0.177
3
Detector on poly at +1250V
255
Yes
2774
300
9.25
0.176
4
Detector on poly at +1250V
255
Yes
2790
300
9.30
0.176
5
Detector on poly at +1250V
255
Yes
2875
300
9.58
0.179
2 1/8" Purple poly (one brick) no thermalizer
1250V source in
Run Number
Configuration
Discriminator Threshold (mV)
Cf-252 Button Source
Counts
Run Time (Sec)
Count Rate (Hz)
Uncertainty
1
Detector on poly at +1250V
255
Yes
2118
300
7.06
0.153
2
Detector on poly at +1250V
255
Yes
2012
300
6.71
0.150
3
Detector on poly at +1250V
255
Yes
2092
300
6.97
0.152
4
Detector on poly at +1250V
255
Yes
2025
300
6.75
0.150
5
Detector on poly at +1250V
255
Yes
2092
300
6.97
0.152
3 1/8" Purple poly (one brick & sheet) no thermalizer
1250V source in
Run Number
Configuration
Discriminator Threshold (mV)
Cf-252 Button Source
Counts
Run Time (Sec)
Count Rate (Hz)
Uncertainty
1
Detector on poly at +1250V
255
Yes
1434
300
4.78
0.126
2
Detector on poly at +1250V
255
Yes
1348
300
4.49
0.122
3
Detector on poly at +1250V
255
Yes
1489
300
4.96
0.129
4
Detector on poly at +1250V
255
Yes
1393
300
4.64
0.124
5
Detector on poly at +1250V
255
Yes
1372
300
4.57
0.124
4 1/4" Purple poly (two bricks) no thermalizer
1250V source in
Run Number
Configuration
Discriminator Threshold (mV)
Cf-252 Button Source
Counts
Run Time (Sec)
Count Rate (Hz)
Uncertainty
1
Detector on poly at +1250V
255
Yes
1093
300
3.64
0.110
2
Detector on poly at +1250V
255
Yes
1068
300
3.56
0.109
3
Detector on poly at +1250V
255
Yes
1116
300
3.72
0.111
4
Detector on poly at +1250V
255
Yes
1031
300
3.44
0.107
5
Detector on poly at +1250V
255
Yes
1142
300
3.81
0.113
6 3/8" Purple poly (two bricks) no thermalizer
1250V source in
Run Number
Configuration
Discriminator Threshold (mV)
Cf-252 Button Source
Counts
Run Time (Sec)
Count Rate (Hz)
Uncertainty
1
Detector on poly at +1250V
255
Yes
743
300
2.48
0.091
2
Detector on poly at +1250V
255
Yes
694
300
2.31
0.088
3
Detector on poly at +1250V
255
Yes
756
300
2.52
0.092
4
Detector on poly at +1250V
255
Yes
735
300
2.45
0.090
5
Detector on poly at +1250V
255
Yes
745
300
2.48
0.091
8 1/2" Purple poly (two bricks) no thermalizer
1250V source in
Run Number
Configuration
Discriminator Threshold (mV)
Cf-252 Button Source
Counts
Run Time (Sec)
Count Rate (Hz)
Uncertainty
1
Detector on poly at +1250V
255
Yes
662
300
2.21
0.086
2
Detector on poly at +1250V
255
Yes
586
300
1.95
0.081
3
Detector on poly at +1250V
255
Yes
613
300
2.04
0.083
4
Detector on poly at +1250V
255
Yes
560
300
1.87
0.079
5
Detector on poly at +1250V
255
Yes
622
300
2.07
0.083
Purple poly with Thermalizer
2 1/8" Purple poly (one brick) with thermalizer
1250V Thermalized source
Run Number
Configuration
Discriminator Threshold (mV)
Cf-252 Button Source
Counts
Run Time (Sec)
Count Rate (Hz)
Uncertainty
1
Detector on poly at +1250V
255
Yes, thermalized
2117
300
7.06
0.153
2
Detector on poly at +1250V
255
Yes, thermalized
1869
300
6.23
0.144
3
Detector on poly at +1250V
255
Yes, thermalized
1836
300
6.12
0.143
4
Detector on poly at +1250V
255
Yes, thermalized
1893
300
6.31
0.145
5
Detector on poly at +1250V
255
Yes, thermalized
1886
300
6.29
0.145
Green Poly without Thermalizer
1" Green poly, no thermalizer
1250V source in
Run Number
Configuration
Discriminator Threshold (mV)
Cf-252 Button Source
Counts
Run Time (Sec)
Count Rate (Hz)
Uncertainty
1
Detector on poly at +1250V
255
Yes
2566
300
8.55
0.169
2
Detector on poly at +1250V
255
Yes
2627
300
8.76
0.171
3
Detector on poly at +1250V
255
Yes
2559
300
8.53
0.169
4
Detector on poly at +1250V
255
Yes
2562
300
8.54
0.169
5
Detector on poly at +1250V
255
Yes
2660
300
8.87
0.172
2" Green poly (one brick) no thermalizer
1250V source in
Run Number
Configuration
Discriminator Threshold (mV)
Cf-252 Button Source
Counts
Run Time (Sec)
Count Rate (Hz)
Uncertainty
1
Detector on poly at +1250V
255
Yes
2176
300
7.25
0.155
2
Detector on poly at +1250V
255
Yes
2070
300
6.90
0.152
3
Detector on poly at +1250V
255
Yes
2055
300
6.85
0.151
4
Detector on poly at +1250V
255
Yes
2131
300
7.10
0.154
5
Detector on poly at +1250V
255
Yes
1957
300
6.52
0.147
3" Green poly (one brick & sheet) no thermalizer
1250V source in
Run Number
Configuration
Discriminator Threshold (mV)
Cf-252 Button Source
Counts
Run Time (Sec)
Count Rate (Hz)
Uncertainty
1
Detector on poly at +1250V
255
Yes
1345
300
4.48
0.122
2
Detector on poly at +1250V
255
Yes
1335
300
4.45
0.122
3
Detector on poly at +1250V
255
Yes
1295
300
4.32
0.120
4
Detector on poly at +1250V
255
Yes
1384
300
4.61
0.124
5
Detector on poly at +1250V
255
Yes
1297
300
4.32
0.120
4" Green poly (two bricks) no thermalizer
1250V source in
Run Number
Configuration
Discriminator Threshold (mV)
Cf-252 Button Source
Counts
Run Time (Sec)
Count Rate (Hz)
Uncertainty
1
Detector on poly at +1250V
255
Yes
1056
300
3.52
0.108
2
Detector on poly at +1250V
255
Yes
1085
300
3.62
0.110
3
Detector on poly at +1250V
255
Yes
1151
300
3.84
0.113
4
Detector on poly at +1250V
255
Yes
1064
300
3.55
0.109
5
Detector on poly at +1250V
255
Yes
1059
300
3.53
0.108
6" Green poly (three bricks) no thermalizer
1250V source in
Run Number
Configuration
Discriminator Threshold (mV)
Cf-252 Button Source
Counts
Run Time (Sec)
Count Rate (Hz)
Uncertainty
1
Detector on poly at +1250V
255
Yes
728
300
2.43
0.090
2
Detector on poly at +1250V
255
Yes
737
300
2.46
0.090
3
Detector on poly at +1250V
255
Yes
759
300
2.53
0.092
4
Detector on poly at +1250V
255
Yes
717
300
2.39
0.089
5
Detector on poly at +1250V
255
Yes
764
300
2.55
0.092
8" Green poly (four bricks) no thermalizer
1250V source in
Run Number
Configuration
Discriminator Threshold (mV)
Cf-252 Button Source
Counts
Run Time (Sec)
Count Rate (Hz)
Uncertainty
1
Detector on poly at +1250V
255
Yes
612
300
2.04
0.082
2
Detector on poly at +1250V
255
Yes
606
300
2.02
0.082
3
Detector on poly at +1250V
255
Yes
582
300
1.94
0.080
4
Detector on poly at +1250V
255
Yes
606
300
2.04
0.082
5
Detector on poly at +1250V
255
Yes
597
300
1.99
0.081
Green Poly with Thermalizer
2 1/8" Green poly (one brick) with thermalizer
1250V Thermalized source
Run Number
Configuration
Discriminator Threshold (mV)
Cf-252 Button Source
Counts
Run Time (Sec)
Count Rate (Hz)
Uncertainty
1
Detector on poly at +1250V
255
Yes, thermalized
1904
300
6.35
0.145
2
Detector on poly at +1250V
255
Yes, thermalized
1829
300
6.10
0.143
3
Detector on poly at +1250V
255
Yes, thermalized
1851
300
6.17
0.143
4
Detector on poly at +1250V
255
Yes, thermalized
1887
300
6.29
0.145
5
Detector on poly at +1250V
255
Yes, thermalized
1914
300
6.38
0.146
Virgin Poly
1" Virgin Poly (one sheet)
1250V Source In
Run Number
Configuration
Discriminator Threshold (mV)
Cf-252 Button Source
Counts
Run Time (Sec)
Count Rate (Hz)
Uncertainty
1
Detector on poly at +1250V
255
Yes
12743
300
42.47
0.376
2
Detector on poly at +1250V
255
Yes
13109
300
43.69
0.382
3
Detector on poly at +1250V
255
Yes
13052
300
43.51
0.381
4
Detector on poly at +1250V
255
Yes
13136
300
43.79
0.382
5
Detector on poly at +1250V
255
Yes
13064
300
43.55
0.381
2" Virgin Poly (one brick)
1250V Source In
Run Number
Configuration
Discriminator Threshold (mV)
Cf-252 Button Source
Counts
Run Time (Sec)
Count Rate (Hz)
Uncertainty
1
Detector on poly at +1250V
255
Yes
11950
300
2
Detector on poly at +1250V
255
Yes
12088
300
3
Detector on poly at +1250V
255
Yes
12068
300
4
Detector on poly at +1250V
255
Yes
12163
300
5
Detector on poly at +1250V
255
Yes
12183
300
3" Virgin Poly (one sheet & one brick)
1250V Source In
Run Number
Configuration
Discriminator Threshold (mV)
Cf-252 Button Source
Counts
Run Time (Sec)
Count Rate (Hz)
Uncertainty
1
Detector on poly at +1250V
255
Yes
9185
300
2
Detector on poly at +1250V
255
Yes
9091
300
3
Detector on poly at +1250V
255
Yes
9040
300
4
Detector on poly at +1250V
255
Yes
9211
300
5
Detector on poly at +1250V
255
Yes
9035
300
4" Virgin Poly (two bricks)
1250V Source In
Run Number
Configuration
Discriminator Threshold (mV)
Cf-252 Button Source
Counts
Run Time (Sec)
Count Rate (Hz)
Uncertainty
1
Detector on poly at +1250V
255
Yes
5924
300
2
Detector on poly at +1250V
255
Yes
6232
300
3
Detector on poly at +1250V
255
Yes
6006
300
4
Detector on poly at +1250V
255
Yes
5978
300
5
Detector on poly at +1250V
255
Yes
6222
300
6" Virgin Poly (3 bricks)
1250V Source In
Run Number
Configuration
Discriminator Threshold (mV)
Cf-252 Button Source
Counts
Run Time (Sec)
Count Rate (Hz)
Uncertainty
1
Detector on poly at +1250V
255
Yes
2837
300
2
Detector on poly at +1250V
255
Yes
2985
300
3
Detector on poly at +1250V
255
Yes
3019
300
4
Detector on poly at +1250V
255
Yes
2912
300
5
Detector on poly at +1250V
255
Yes
3009
300
8" Virgin Poly (four bricks)
1250V Source In
Run Number
Configuration
Discriminator Threshold (mV)
Cf-252 Button Source
Counts
Run Time (Sec)
Count Rate (Hz)
Uncertainty
1
Detector on poly at +1250V
255
Yes
1974
300
2
Detector on poly at +1250V
255
Yes
2006
300
3
Detector on poly at +1250V
255
Yes
1975
300
4
Detector on poly at +1250V
255
Yes
2069
300
5
Detector on poly at +1250V
255
Yes
1990
300
Results
Posted 6/22/21
Completed attenuation measurements with differing thicknesses of Borated Poly vs unborated poly.
The purple and green poly definitely have some boron concentration in them. The fitted curves are the same within uncertainty, so it should not matter which type of borated poly is used in our experimental setup.