|  Run Number || configuration
 +
|-
 +
|  6819  ||    Cs-137 source at location of Cf-252, no Cf-252 or Cd target in apparatus
 +
|-
 +
| 6820 ||  start time:  16:04:33  04/26/2021  Cs-137 out, Cd in , Cf-252 out. NaI at closest possible.  stop time: 16:08:34 (241 seconds)
 +
|-
 +
| 6821 ||  start time:  16:11:49  04/26/2021  Cs-137 out, Cd in , Cf-252 in , Poly thermalizer 1/2" in. NaI at closest possible.  stop time: 16:22:52  (663 sec)
 +
|-
 +
| 6822 ||  start time:  16:23:54  04/26/2021  Cs-137 out, Cd in , Cf-252 out , Poly thermalizer 1/2" in. NaI at closest possible.  stop time:16:34:38 (673 sec)
 +
|-
 +
| 6823 ||  start time: 16:35:44  04/26/2021  Cs-137 out, Cd out , Cf-252 out , Poly thermalizer 1/2" in. NaI at closest possible.  stop time:16:46
 +
|-
 +
| 6824 ||  start time: 16:35:44  04/26/2021  Cf-252 in , Poly thermalizer 1/2" in. ,Cd in sandwhich ,  NaI at closest possible.  stop time:16:46
 +
|-
 +
| 6825 ||  start time:  16:53:55 04/26/2021  Cf-252 in 6 in away, 1" lead,  , Poly thermalizer 1/2" in. ,Cd in sandwhich ,  NaI at closest possible.  stop time:16:54:58
 +
|-
 +
| 6826 ||  start time: 16:57:39  04/26/2021  Cf-252 in 6 in away, 2" lead,  , Poly thermalizer 1/2" in. ,Cd in sandwhich ,  NaI at closest possible.  stop time:16:58:49
 +
|-
 +
| 6827 ||  start time: 16:59:13  04/26/2021  Cf-252 in 6 in away, 2" lead,  , Poly thermalizer 1/2" in. ,Cd OUT sandwhich ,  NaI at closest possible.  stop time:17:00:15
 +
|-
 +
|}
  
  

Revision as of 19:36, 14 May 2021

Preliminary Measurements

Detector JD-766 on experimental table to measure background count rate to be used in attenuation measurements.
Run Number configuration
6819 Cs-137 source at location of Cf-252, no Cf-252 or Cd target in apparatus
6820 start time: 16:04:33 04/26/2021 Cs-137 out, Cd in , Cf-252 out. NaI at closest possible. stop time: 16:08:34 (241 seconds)
6821 start time: 16:11:49 04/26/2021 Cs-137 out, Cd in , Cf-252 in , Poly thermalizer 1/2" in. NaI at closest possible. stop time: 16:22:52 (663 sec)
6822 start time: 16:23:54 04/26/2021 Cs-137 out, Cd in , Cf-252 out , Poly thermalizer 1/2" in. NaI at closest possible. stop time:16:34:38 (673 sec)
6823 start time: 16:35:44 04/26/2021 Cs-137 out, Cd out , Cf-252 out , Poly thermalizer 1/2" in. NaI at closest possible. stop time:16:46
6824 start time: 16:35:44 04/26/2021 Cf-252 in , Poly thermalizer 1/2" in. ,Cd in sandwhich , NaI at closest possible. stop time:16:46
6825 start time: 16:53:55 04/26/2021 Cf-252 in 6 in away, 1" lead, , Poly thermalizer 1/2" in. ,Cd in sandwhich , NaI at closest possible. stop time:16:54:58
6826 start time: 16:57:39 04/26/2021 Cf-252 in 6 in away, 2" lead, , Poly thermalizer 1/2" in. ,Cd in sandwhich , NaI at closest possible. stop time:16:58:49
6827 start time: 16:59:13 04/26/2021 Cf-252 in 6 in away, 2" lead, , Poly thermalizer 1/2" in. ,Cd OUT sandwhich , NaI at closest possible. stop time:17:00:15