Difference between revisions of "UnderGraduate Neutron Correlations Lab"
Line 76: | Line 76: | ||
|} | |} | ||
+ | =data 5/3/21= | ||
+ | |||
+ | Set up: | ||
+ | * Lead: Detector surrounded on 4 sides by 1" lead. Front end 4" of lead. Back end exposed. | ||
+ | * Poly: 40cm of green poly between lead and source. No poly elsewhere. | ||
+ | |||
+ | |||
+ | Source in 1428 | ||
+ | Source out 1318 | ||
+ | Source out 1361 | ||
+ | Source out 1393 | ||
[[https://wiki.iac.isu.edu/index.php/Main_Page]] | [[https://wiki.iac.isu.edu/index.php/Main_Page]] |
Revision as of 19:09, 3 May 2021
[[1]]
NaI detector setup
Creating ROOT data files
source ~/CODA/setup
/home/daq/CODA/CODAreader/ROOT_V5.34/PAA/evio2nt -fr6815.dat > /dev/null
Analyzing ROOT data file
root -l r8735.root
to draw a histogram for Peak ADC channel 4
PAA->Draw("PADC.PADC785N[4]>>(4096,0,4096)")
To scale the histogram using an energy calibration of 0.45 keV/channel
PAA->Draw("PADC.PADC785N[4]*0.45>>(4096,0,4096)")
To save thehistogram under the name Cs137
PAA->Draw("PADC.PADC785N[4]*0.45>>Cs137(4096,0,4096)")
To normalize the histogram by a run time of 2600 seconds
1/3600=0.0002778
Cs137->Scale(0.0002778) Cs137->Draw();
run 6816 background (~300Hz) 1/47 = 0.021277
run 6817 signal (~600 Hz) 1/75 =0.013333
https://wiki.iac.isu.edu/index.php/File:NaI_Cs137_4-22-21.png
data 4/26/21
Run Number | configuration |
6819 | Cs-137 source at location of Cf-252, no Cf-252 or Cd target in apparatus |
6820 | start time: 16:04:33 04/26/2021 Cs-137 out, Cd in , Cf-252 out. NaI at closest possible. stop time: 16:08:34 (241 seconds) |
6821 | start time: 16:11:49 04/26/2021 Cs-137 out, Cd in , Cf-252 in , Poly thermalizer 1/2" in. NaI at closest possible. stop time: 16:22:52 (663 sec) |
6822 | start time: 16:23:54 04/26/2021 Cs-137 out, Cd in , Cf-252 out , Poly thermalizer 1/2" in. NaI at closest possible. stop time:16:34:38 (673 sec) |
6823 | start time: 16:35:44 04/26/2021 Cs-137 out, Cd out , Cf-252 out , Poly thermalizer 1/2" in. NaI at closest possible. stop time:16:46 |
6824 | start time: 16:35:44 04/26/2021 Cf-252 in , Poly thermalizer 1/2" in. ,Cd in sandwhich , NaI at closest possible. stop time:16:46 |
6825 | start time: 16:53:55 04/26/2021 Cf-252 in 6 in away, 1" lead, , Poly thermalizer 1/2" in. ,Cd in sandwhich , NaI at closest possible. stop time:16:54:58 |
6826 | start time: 16:57:39 04/26/2021 Cf-252 in 6 in away, 2" lead, , Poly thermalizer 1/2" in. ,Cd in sandwhich , NaI at closest possible. stop time:16:58:49 |
6827 | start time: 16:59:13 04/26/2021 Cf-252 in 6 in away, 2" lead, , Poly thermalizer 1/2" in. ,Cd OUT sandwhich , NaI at closest possible. stop time:17:00:15 |
data 5/3/21
Set up:
- Lead: Detector surrounded on 4 sides by 1" lead. Front end 4" of lead. Back end exposed.
- Poly: 40cm of green poly between lead and source. No poly elsewhere.
Source in 1428
Source out 1318
Source out 1361
Source out 1393
[[2]]