Difference between revisions of "UNCL Runs"

From New IAC Wiki
Jump to navigation Jump to search
Line 53: Line 53:
  
 
[[File:Run6714_6715.jpg]]
 
[[File:Run6714_6715.jpg]]
 +
 +
Run 6738
 +
 +
Date: 9/8/2020
 +
 +
Start time: 08/25/2020 21:13:42
 +
 +
Stop time: 09/08/2020 15:46:??
 +
 +
Events: 175800
 +
 +
 +
 +
09/08/2020 3:50pm Adjusted Right photon detector to -1400V
 +
 +
 +
Run 6739
 +
 +
Date: 9/8/2020
 +
 +
Start time: 9/8/2020  ~3:50pm
 +
 +
Stop time:
 +
 +
Events:
 +
 +
Adjusted Right photon detector to -1400V
  
  
 
[[CH_UNCL#UNCL_Runs]]
 
[[CH_UNCL#UNCL_Runs]]

Revision as of 21:53, 8 September 2020

CH_UNCL#UNCL_Runs

A log book of runs taken in UNCL

Run # Start Time End Time Source Im/Out Dexcription
6705 8/10/2020 18:19:32 8/10/2020 18:57:21 In Source in, 54 cm from neutron UNCL 2, Total Events: 5987,9" sep between photon scintillators ,Voltages: Left: -1200,Right: -1200,UNCL Top/Bottom: -1450,Threshold: 15 mV
6736 8/24/2020 13:50:59 Out The calibration 400 ns time pulse :UNCL->Draw("(evt.TDC1290A[2][1]-evt.TDC1290A[1][1])/10"), The time difference between two gamma detectors: UNCL->Draw("(evt.TDC1290A[1][2]-evt.TDC1290A[1][3])/10"), The time difference between two neutron detectors 1.25 m away from photon detectors: UNCL->Draw("(evt.TDC1290A[1][11]-evt.TDC1290A[1][12])/10"), time difference between two neutron detectors 2.5m away from gamma detectors:UNCL->Draw("(evt.TDC1290A[1][8]-evt.TDC1290A[1][7])/10"), HV for gamma detector in channel 2 is too low, counts in gamma detector channel 2 are a factor of 7 lower than counts in gamma detector in channel 1


Run 6714

Date: 8/12/2020

Start time: 15:50:35

Stop time: 16:22:53


1/(Run Time) Hz = 5.15995872e−4 Source in, 1.25 cm from neutron UNCL 2

Total Events: 1350

9" sep between photon scintillators

Voltages:

Left: -1200

Right: -1200

UNCL Top/Bottom: -1450

Threshold: 15 mV


Run 6715

Date: 8/12/2020

Start time: 16:??:??

Stop time: 04:41:??

~1/(RunTime) Hz = 2.314814815e−5

Run6714 6715.jpg

Run 6738

Date: 9/8/2020

Start time: 08/25/2020 21:13:42

Stop time: 09/08/2020 15:46:??

Events: 175800


09/08/2020 3:50pm Adjusted Right photon detector to -1400V


Run 6739

Date: 9/8/2020

Start time: 9/8/2020 ~3:50pm

Stop time:

Events:

Adjusted Right photon detector to -1400V


CH_UNCL#UNCL_Runs