Line 77: | Line 77: | ||
− | we can define a differential scattering cross-section, <math>\frac{d\sigma(\theta')}{d{\mit\Omega}'}</math>, in the laboratory frame, where <math>d{\mit\Omega}'=2\pi\,\sin\ | + | we can define a differential scattering cross-section, <math>\frac{d\sigma(\theta')}{d{\mit\Omega}'}</math>, in the laboratory frame, where <math>d{\mit\Omega}'=2\pi\,\sin\theta'\,d\theta'</math> is an element of solid angle in this frame. Thus, <math>\frac{d\sigma(\theta)}{d{\mit\Omega}'}\,d{\mit\Omega}'</math> is the effective cross-sectional area in the laboratory frame for scattering into the range of scattering angles <math>\theta</math> to <math>\theta+d\theta</math>. Likewise, <math>(d\sigma(\theta)/d{\mit\Omega})\,d{\mit\Omega}</math>is the effective cross-sectional area in the center of mass frame for scattering into the range of scattering angles <math>\theta </math> to <math>\theta+d\theta</math>. Note that <math>d{\mit\Omega} =2\pi\,\sin\theta\,d\theta</math>. However, a cross-sectional area is not changed when we transform between different inertial frames. Hence, we can write |
Revision as of 15:47, 23 July 2018
General Occupancy
The occupancy measures the number of particles interactions per a detector cell per an event. For the CLAS12 drift chamber, there are 112 wires on each layer, with 12 layers within a region, giving 1344 cells. This can simply be defined as the "Unweighted Occupancy" for the CLAS12 DC and follows the equation:
where
CLAS12 DC Occupancy
The registering of a "hit" takes a finite time in which the detector and its associated electronics are not able to register an additional signal if it occurs. This time window is known as the "dead time" during which only limited events are registered. For Region 1:
Since the events are simulated outside the dead time constraints of the DC, we can factor in the number of event windows that occur by dividing the dead time window per region by the time that would have been required to produce the number of incident electrons given a known current.
When applying the Moller differential cross-section as a weight, this gives the CLAS12 occupancy as:
Weighted Hits Occupancy
Using the definition of the cross-section:
where the flux is defined as:
Making some assumptions that the flux can be taken over an same time range as the time found in the cross-section, which allows
For a LH2 target of length 5cm.
Additionally, for Moller Scattering, we can assume that almost 100% of the incident electrons occur as events.
This allows us to rewrite the cross-section expression as,
we can define a differential scattering cross-section, , in the laboratory frame, where is an element of solid angle in this frame. Thus, is the effective cross-sectional area in the laboratory frame for scattering into the range of scattering angles to . Likewise, is the effective cross-sectional area in the center of mass frame for scattering into the range of scattering angles to . Note that . However, a cross-sectional area is not changed when we transform between different inertial frames. Hence, we can write
Since the expression for the differential cross-section for Moller Scattering is well know, we can solve for the minimum angle detected by the DC (5 degrees in Theta).