| Mass of Quartz used in simulation: <math>(\pi(1.27)^{2}*(2.54))*(2.32)=29.8593g</math> | Mass of Quartz used in simulation: <math>(\pi(1.27)^{2}*(2.54))*(2.32)=29.8593g</math> | ||
| − | Scaling deposited energy by 1000 to account for only shooting a 1000th of a pulse, the deposited energy becomes <math>4.71875*10^{12} MeV</math>   | + | Scaling deposited energy by 1000 to account for only shooting a 1000th of a pulse, the deposited energy becomes <math>4.71875*10^{12} \MeV</math>   | 
| ---- | ---- | ||
| [[Thesis]] | [[Thesis]] | ||
Revision as of 18:14, 16 April 2018
Date
85 useable OSLs
Machine: 24b Linac
Beam Energy: 8 MeV
Rep Rate: Max (180Hz)?
- Shot # - Start Time - End Time - Number of OSLs - Distance to end of beampipe - Beam Current - Aluminum Brick - Background Subtracted PMT Counts - 1 - 7am - 7:15am - 1 - 25cm - amps - Out - 2 - 7:20am - 7:35am - 1 - 25cm - amps - Out - 3 - 7:40am - 7:55am - 1 - 25cm - amps - Out - 4 - 8:00 - 8:20 - 1 - 25cm - amps - Out - 5 - 1 - 25cm - amps - Out - 6 - 1 - 25cm - amps - In - 7 - 1 - 25cm - amps - In - 8 - 1 - 25cm - amps - In - 9 - 1 - 25cm - amps - In - 10 - 1 - 25cm - amps - In - 11 - 10 - 25cm - amps - Out - 12 - 10 - 25cm - amps - Out - 13 - 10 - 25cm - amps - Out - 14 - 10 - 25cm - amps - Out - 15 - 10 - 25cm - amps - Out - 16 - 10 - 25cm - amps - In - 17 - 15 - 25cm - amps - In 
Calculations
Assuming and a pulse width of
Then
OSL Crystal density
Mass of a single OSL crystal:
Absorbed Dose Information
Quartz
of a pulse. ~62mil e- simulated, ~62bil e- per pulse. With beam parameters given above.
Deposited Energy:
Quartz density
Mass of Quartz used in simulation:
Scaling deposited energy by 1000 to account for only shooting a 1000th of a pulse, the deposited energy becomes