This will be a detailed explanation of how to trace the isotope of interest's activity back to its original value. The sample of interest here is the oven ash sample with inventory number 170063.  
+
This will be a detailed explanation of how to trace the isotope of interest's activity back to its original value. The sample of interest here is the oven ash sample with inventory number 170063. The measurement was made on Detector A at the IAC and it was a split run using a Co-60 flag to denote the changing of samples between a pure selenium sample and a mixture of selenium and sage ash. The target information can be found below:
  
 
==Thin Window Histograms==
 
==Thin Window Histograms==
Line 25: Line 25:
  
 
<math> \sigma_{N} = \sqrt{N} </math>
 
<math> \sigma_{N} = \sqrt{N} </math>
 +
 +
==Dealing With Background==
 +
 +
Now that I have discussed how to get the number of counts along with the uncertainty in the number of counts, I will now discuss how to remove the background from a signal.

Revision as of 16:32, 29 November 2017

This will be a detailed explanation of how to trace the isotope of interest's activity back to its original value. The sample of interest here is the oven ash sample with inventory number 170063. The measurement was made on Detector A at the IAC and it was a split run using a Co-60 flag to denote the changing of samples between a pure selenium sample and a mixture of selenium and sage ash. The target information can be found below:

Thin Window Histograms

Since the resolution of Detector A at the IAC is about 1 keV, the window in which the signal is viewed should have a width of 2 (whether you plot channel number or energy along the horizontal axis). The signals were fit with a function of the form

[math] f(x) = C + Ae^{\frac{(x-\overline{x})^2}{2 \sigma^2}} [/math]


Here, the constant value is to assess the value for the background. The background must be removed from the signal in order to have a more accurate analysis as it is not a part of the signal that we are interested in. Below are sample plots of the original signal and the signal viewed in a thin 2 channel window:

170063 PureSe ThinWindow 400 640Sec.png


170063 PureSe 400 640Sec OGWindow.png


This signal corresponds to the 103 keV line of Se-81. I plotted channel number instead of energy to maintain integer bins and avoid a picket fencing effect in the signal.

In looking at the thin window, the total number of counts within the window is given by the "Integral" value in the statistics box, which I will denote as N.

[math] Stats Box Integral = N [/math]

Since this is a counting experiment, the error in the signal will be given by

[math] \sigma_{N} = \sqrt{N} [/math]

Dealing With Background

Now that I have discussed how to get the number of counts along with the uncertainty in the number of counts, I will now discuss how to remove the background from a signal.