Due to the difficulty in getting the activity ratios to match the expected values, I decided to investigate the dead time of the detector in use (Detector A). Below is a table of values used to generate the plot. This will also give the reader a good idea of what the dead times are for certain count rates.
 
Due to the difficulty in getting the activity ratios to match the expected values, I decided to investigate the dead time of the detector in use (Detector A). Below is a table of values used to generate the plot. This will also give the reader a good idea of what the dead times are for certain count rates.
 +
 +
{| border="3"  cellpadding="5" cellspacing="0"
 +
||Count Rate (Hz) || % Dead
 +
|-
 +
||129.47 +/- 7.84 || 0.24 +/- 0.10
 +
|-
 +
||154.33 +/- 10.36 || 0.29 +/- 0.11
 +
|-
 +
||194.83 +/- 8.36 || 0.41 +/- 0.11
 +
|-
 +
||253.69 +/- 14.05 || 0.51 +/- 0.18
 +
|-
 +
||257.11 +/- 11.24 || 0.53 +/- 0.14
 +
|-
 +
||338.8 +/- 11.68 || 0.65 +/- 0.15
 +
|-
 +
||477.61 +/- 15.06 || 0.84 +/- 0.16
 +
|-
 +
||619.3 +/- 10.56 || 1.34 +/- 0.18
 +
|-
 +
||680.83 +/- 17.5 || 1.33 +/- 0.23
 +
|-
 +
||807.37 +/- 15.85 || 1.55 +/- 0.18
 +
|-
 +
||889.6 +/- 16.22 || 1.65 +/- 0.34
 +
|-
 +
||1051.33 +/- 26.74 || 1.92 +/- 0.26
 +
|-
 +
||1213.93 +/- 23.62 || 2.26 +/- 0.33
 +
|-
 +
|| 1389.45 +/- 24.75 || 2.53 +/- 0.31
 +
|-
 +
||1628.47 +/- 17.17 || 3.06 +/- 0.30
 +
|-
 +
||2084.6 +/- 33.77 || 3.95 +/- 0.42
 +
|-
 +
||2576.5 +/- 31.53 || 5.06 +/- 0.39
 +
|-
 +
||3058.20 +/- 35.62 || 5.87 +/- 0.54
 +
|-
 +
||3362.13 +/- 23.12 || 6.59 +/- 0.43
 +
|-
 +
||4067.2 +/- 45.37 | 8.18 +/- 0.66
 +
|-
 +
||4564.37 +/- 61.94 || 9.09 +/- 0.60
 +
|-
 +
||5511.6 +/- 64.60 || 10.86 +/- 0.85
 +
|-
 +
|}

Revision as of 18:14, 16 November 2017

Due to the difficulty in getting the activity ratios to match the expected values, I decided to investigate the dead time of the detector in use (Detector A). Below is a table of values used to generate the plot. This will also give the reader a good idea of what the dead times are for certain count rates.

Count Rate (Hz) % Dead
129.47 +/- 7.84 0.24 +/- 0.10
154.33 +/- 10.36 0.29 +/- 0.11
194.83 +/- 8.36 0.41 +/- 0.11
253.69 +/- 14.05 0.51 +/- 0.18
257.11 +/- 11.24 0.53 +/- 0.14
338.8 +/- 11.68 0.65 +/- 0.15
477.61 +/- 15.06 0.84 +/- 0.16
619.3 +/- 10.56 1.34 +/- 0.18
680.83 +/- 17.5 1.33 +/- 0.23
807.37 +/- 15.85 1.55 +/- 0.18
889.6 +/- 16.22 1.65 +/- 0.34
1051.33 +/- 26.74 1.92 +/- 0.26
1213.93 +/- 23.62 2.26 +/- 0.33
1389.45 +/- 24.75 2.53 +/- 0.31
1628.47 +/- 17.17 3.06 +/- 0.30
2084.6 +/- 33.77 3.95 +/- 0.42
2576.5 +/- 31.53 5.06 +/- 0.39
3058.20 +/- 35.62 5.87 +/- 0.54
3362.13 +/- 23.12 6.59 +/- 0.43
4067.2 +/- 45.37 | 8.18 +/- 0.66
4564.37 +/- 61.94 9.09 +/- 0.60
5511.6 +/- 64.60 10.86 +/- 0.85