Difference between revisions of "Se170063"
(→Energy) |
(→Energy) |
||
Line 15: | Line 15: | ||
[[LB May Calibration 2017]] | [[LB May Calibration 2017]] | ||
+ | |||
+ | The Calibration for Detector A was done on the morning of 5/23/17 with the MPA software using the thorium rods (as the calibration was fairly close already) and the correction values were found to be A = -2.8392 +/- 0.592828 , B = 0.815444 +/- 0.000630482 | ||
=Halflife= | =Halflife= |
Revision as of 20:31, 7 September 2017
PAA_Selenium/Soil_Experiments#Selenium_Sample_Analysis
Sample Description
The sample was placed in an aluminum cylinder that was to be irradiated. The target components consisted of a nickel foil on the front of the cylinder with 2 pure selenium pellets under the foil, but still outside the cylinder. Inside the target there was burnt sagebrush ash, which was burned with a blowtorch, and selenium. Below are the masses of the components
Nickel Foil: 0.2783g
Outer Se Pellets: 0.0971g
Sage Ash: 0.5111g
Inner Se Pellets: 0.0523g
Energy
The Calibration for Detector A was done on the morning of 5/23/17 with the MPA software using the thorium rods (as the calibration was fairly close already) and the correction values were found to be A = -2.8392 +/- 0.592828 , B = 0.815444 +/- 0.000630482
Halflife
Efficiency
Activity
Runlist
Table with dates and filename and locations on daq1