Difference between revisions of "8-10-2017"

From New IAC Wiki
Jump to navigation Jump to search
m
 
Line 34: Line 34:
 
| 6561 ||Integral=  313pV*s +- 10 peak = 1.1A || DU-238 R45020  ||  10.5 MeV (1110 Gauss) , 3 ns FWHM pulse width , 1.1 A Peak , 240 Hz  ||[[File:R6561.png|230px]]  ||[[File:R6561Nmon.png|230px]]  || ||  
 
| 6561 ||Integral=  313pV*s +- 10 peak = 1.1A || DU-238 R45020  ||  10.5 MeV (1110 Gauss) , 3 ns FWHM pulse width , 1.1 A Peak , 240 Hz  ||[[File:R6561.png|230px]]  ||[[File:R6561Nmon.png|230px]]  || ||  
 
|-
 
|-
| 6562 ||colspan=3| COSMIC RUN ||[[File:R6561.png|230px]]  ||[[File:R6561Nmon.png|230px]]  || ||  
+
| 6562 ||colspan=3| COSMIC RUN ||[[File:R6562.png|230px]]  ||[[File:R6562Nmon.png|230px]]  || ||  
 
|}
 
|}
  

Latest revision as of 18:29, 11 August 2017

2nCor_44#Aug_2017

Aug_2017_ChkList#Checklist

8-08-2017

8-09-2017

8-11-2017

Run # Charge/pulse Target Configuration Individual histos + rates Neutron Monitor no top bottom coin. other
6551 Integral= 280 pV*s +-10 peak = 1.1A D2O 10.5 MeV (1113 Gauss) , 3 ns FWHM pulse width , 1.1 A Peak , 240 Hz R6551.png R6551Nmon.png 230px
6552 Integral= 260 pV*s +-10 peak = 1.1A Al 10.5 MeV (1113 Gauss) , 3 ns FWHM pulse width , 1.1 A Peak , 240 Hz R6552.png R6552Nmon.png 230px
6553 Integral= 260 pV*s +-10 peak = 1.1A DU-238 R45020 10.5 MeV (1113 Gauss) , 3 ns FWHM pulse width , 1.1 A Peak , 240 Hz R6553.png R6553Nmon.png 230px
6554 Integral= 265 pV*s +-10 peak = 1.1A DU-238 R45020 10.5 MeV (1113 Gauss) , 3 ns FWHM pulse width , 1.1 A Peak , 240 Hz R6554.png R6554Nmon.png
6555 Integral= 265 pV*s +-10 peak = 1.1A DU-238 R45020 10.5 MeV (1113 Gauss) , 3 ns FWHM pulse width , 1.1 A Peak , 240 Hz R6555Nmon.png Bad Run - Weird Start
6556 Integral= 270 pV*s +-10 peak = 1.1A DU-238 R45020 10.5 MeV (1113 Gauss) , 3 ns FWHM pulse width , 1.1 A Peak , 240 Hz R6556.png R6556Nmon.png
6557 Integral= 265 pV*s +-10 peak = 1.1A DU-238 R45020 10.5 MeV (1110 Gauss) , 3 ns FWHM pulse width , 1.1 A Peak , 240 Hz R6557.png R6557Nmon.png prior to run Lemo cable from D330B1.6 to LED was observed to have fallen out of its connector, The HV system control was frozen, ended run after an hour to check accelerator blue tank
6558 Integral= 255pV*s +- 10 peak = 1.1A DU-238 R45020 10.5 MeV (1110 Gauss) , 3 ns FWHM pulse width , 1.1 A Peak , 240 Hz R6558.png R6558Nmon.png
6559 Integral= 302pV*s +- 10 peak = 1.1A DU-238 R45020 10.5 MeV (1110 Gauss) , 3 ns FWHM pulse width , 1.1 A Peak , 240 Hz R6559.png R6559Nmon.png
6560 Integral= 308pV*s +- 10 peak = 1.1A DU-238 R45020 10.5 MeV (1110 Gauss) , 3 ns FWHM pulse width , 1.1 A Peak , 240 Hz R6560.png R6560Nmon.png
6561 Integral= 313pV*s +- 10 peak = 1.1A DU-238 R45020 10.5 MeV (1110 Gauss) , 3 ns FWHM pulse width , 1.1 A Peak , 240 Hz R6561.png R6561Nmon.png
6562 COSMIC RUN R6562.png 230px

Aug_2017_ChkList#Checklist

2nCor_44#Aug_2017