− | ! Run # !! Configuration | + | ! Run # !! RunTime (sec) !! Configuration |
|- | |- | ||
− | |5598 || PAA configuration 10 uCi Na-22 and Co-60 source 32 cm from HpGe face | + | |5598 || || PAA configuration 10 uCi Na-22 and Co-60 source 32 cm from HpGe face |
|- | |- | ||
− | |5599 || PAA configuration Thorium welding rods on HpGe Face | + | |5599 || ||PAA configuration Thorium welding rods on HpGe Face |
|- | |- | ||
− | |5600 || PAA configuration Thorium welding rods on HpGe Face changed threshold from 48 to 57 mV on HpGe trigger | + | |5600 || ||PAA configuration Thorium welding rods on HpGe Face changed threshold from 48 to 57 mV on HpGe trigger |
|- | |- | ||
− | |5602 || PAA configuration Cf source on paperclip, 21 cm of Poly on front HpGe face, HpGe face is 50 cm from Cf source, 4 minute run?, 450 Hz | + | |5602 || ||PAA configuration Cf source on paperclip, 21 cm of Poly on front HpGe face, HpGe face is 50 cm from Cf source, 4 minute run?, 450 Hz |
|- | |- | ||
− | |5603 || PAA configuration Cf source on paperclip, '''Poly is out''', HpGe face is 50 cm from Cf source, 4 minute run , 450 Hz | + | |5603 || ||PAA configuration Cf source on paperclip, '''Poly is out''', HpGe face is 50 cm from Cf source, 4 minute run , 450 Hz |
|- | |- | ||
− | |5607 || FF configuration Cf source on paperclip, 21 cm of Poly on front HpGe face, HpGe face is 50 cm from Cf source, double coincidence between HpGE and small Scint, 5 Hz | + | |5607 || ||FF configuration Cf source on paperclip, 21 cm of Poly on front HpGe face, HpGe face is 50 cm from Cf source, double coincidence between HpGE and small Scint, 5 Hz |
|- | |- | ||
− | |5606 || FF configuration Cf source on paperclip, 21 cm of Poly on front HpGe face, HpGe face is 50 cm from Cf source, 4 minute run , double coincidence between HpGE and small Scint | + | |5606 || || FF configuration Cf source on paperclip, 21 cm of Poly on front HpGe face, HpGe face is 50 cm from Cf source, 4 minute run , double coincidence between HpGE and small Scint |
|- | |- | ||
|} | |} |
Revision as of 22:59, 29 December 2016
Determine impact of Cf source on HpGe detector (see this page). A measurement was done previously with the Cf source and another HpGe detector for 30 minutes.
Run # | RunTime (sec) | Configuration |
---|---|---|
5598 | PAA configuration 10 uCi Na-22 and Co-60 source 32 cm from HpGe face | |
5599 | PAA configuration Thorium welding rods on HpGe Face | |
5600 | PAA configuration Thorium welding rods on HpGe Face changed threshold from 48 to 57 mV on HpGe trigger | |
5602 | PAA configuration Cf source on paperclip, 21 cm of Poly on front HpGe face, HpGe face is 50 cm from Cf source, 4 minute run?, 450 Hz | |
5603 | PAA configuration Cf source on paperclip, Poly is out, HpGe face is 50 cm from Cf source, 4 minute run , 450 Hz | |
5607 | FF configuration Cf source on paperclip, 21 cm of Poly on front HpGe face, HpGe face is 50 cm from Cf source, double coincidence between HpGE and small Scint, 5 Hz | |
5606 | FF configuration Cf source on paperclip, 21 cm of Poly on front HpGe face, HpGe face is 50 cm from Cf source, 4 minute run , double coincidence between HpGE and small Scint |
Run 5569 PADC.PADC785N[15]=78 ADC End of Block fc0002b0 Event#688 ADC End of Block fc00026d Event#621 ADC Ch:0 valid=0 value=0 0 PADC.PADC785N[0]=0